Outline Of Analog Signal Output Circuit - Mitsubishi Electric MELDAS C6 Maintenance Manual

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

6.7 Outline of Analog Signal Output Circuit

The analog signal output circuit can be used only for the FCUA-DX120/DX121/DX140/DX141.
Output circuit
Output conditions
Output impedance
6. CONNECTION OF REMOTE I/O UNIT
6.7 Outline of Analog Signal Output Circuit
R
220Ω
A0
A0*
0V to ±10V (±5%)
Output voltage
Resolution
12bit (±10V × n/4096) (Note)
Load conditions
10kΩ load resistance
220Ω
I - 62
Get other manuals https://www.bkmanuals.com
R
DAC
0
11
(Note) n = (2