Configuring VISM Features
Type the addlnloop command, a line-num argument value, and press Enter to set a specified line to the
Step 6
local loopback state. Specify the line-num argument in the range from 1 to 8.
Use the dellnloop command to remove the local loopback state on a VISM line.
Note
You have completed configuring T1 and E1 lines for your VISM card. Proceed to the
E1 Lines In Service" section on page
Placing T1 and E1 Lines In Service
Type the cnflnis command, a line-num argument value, and press Enter to place a T1 or E1 line in
service. Specify the line-num argument in the range from 1 to 8.
If the VISM card is rebooted, this information configuration using this command is lost.
Note
Placing T1 and E1 Lines Out of Service
Type the cnflnoos command, line-num and oos-method argument values, and press Enter to place a T1
or E1 line out of service. Specify the arguments with the following values:

Configuring the PXM and VISM Cards Clocking Source

Complete the following steps to configure the clocking source on your PXM and VISM cards.
Note
Refer to
Source Selection" section on page 4-69
specifying argument values to configure the clocking source on your PXM and VISM cards.
Step 1
Examine the entire configuration of the MGX 8000 Series platform to determine the single clock source.
The type of equipment connected to the VISM T1 or E1 lines may dictate this choice. If the selected
clock source is from one of the VISM T1 or E1 lines, that line must be connected to port 1 of the VISM
back card. See
Cisco VISM Installation and Configuration Guide
4-14
The VISM CLI has no command for setting a line to the remote loopback state. Use the
cnfbert command on the PXM card to set a line to the remote loopback state.
line-num: In the range from 1 to 8
oos-method:
2 = Forceful
3 = Graceful
Appendix A, "VISM and VISM-PR Card Clocking Options,"
Figure 1-3 on page 1-4
4-14.
for additional instructions on using the commands and
for more information on VISM back cards and port locations.