INTRODUCTION
PRELIMINAR STUDIES AND CONSIDERATIONS
MOUNTING AND CONSTRUCTION
Use and type of reinforcements
If the extension of the overhang is less than 100 mm in length, it is not necessary
to add reinforcements to the frame for normal performance, this in only necessary
for high loading works.
If the extension of the overhang is more than 100 mm in length, reinforcements
should be added on beams of the chassis frame.
The materials used in the reinforcements must match the materials of the original
chassis. They should be placed symmetrically on either side of the frame.
NOTICE
ITo obtain more information about chassis frame material:
See Chapter 4.2.2 "Materials".
The shape of the reinforcements can be as follows:
1
End cross member
2
Low flange
3
Low flange extension
4
Upper flange
Table 1-48 LCV_SPBGC42_012 Reinforcements of the chassis beams
The dimensions of the reinforcements will be determined by the Body Builder.
66
MAINTENANCE AND DAMAGE PREVENTION
POWER TAKE-OFF
5
Upper flange extension
6
Outer reinforcement
7
Inner reinforcement
X
Overhang extension
Body Builder Manual Part II, Specific Book LCV
ELECTRIC AND ELECTRONIC SYSTEMS
WORK ON BASIC VEHICLE
APPENDIX
V1.0, February 2015