9.3 Model Specifications (200 V Class)
*5
The rated output capacity is calculated with a rated output voltage of 220 V.
Model
Maximum Applicable Motor
Output (kW)
Maximum Applicable Motor
Output (HP)
Rated Input
Input
Current
(A)
*3
Rated Output
Capacity
(kVA)
Rated Output
Current (A)
Overload Tolerance
Outputs
Carrier Frequency
Maximum Output Voltage
Maximum Output Frequency
Measures for
DC Reactor
Harmonics
Braking
Braking Transistor
Device
EMC Filter
EMC Filter
IEC61800-3, C2/C3
Rated Voltage/Rated
Frequency
Permitted Voltage Fluctuation -15% to +10%
Power Supply
Permitted Frequency
Fluctuation
Input Power
(kVA)
*1
The maximum applicable motor output complies with 208 V motor ratings as specified in NEC Table 430.250. The rated output
current of the drive output amps must be equal to or more than the motor rated current.
*2
The maximum applicable motor output is based on 4-pole, general-purpose 220 V motor ratings. The rated output current of the drive
output amps must be equal to or more than the motor rated current.
*3
Assumes the value at the rated output current. The input current rating changes when the power supply transformer, input reactor,
wiring connections, or power supply impedance change.
*4
The rated output capacity is calculated with a rated output voltage of 208 V.
*5
The rated output capacity is calculated with a rated output voltage of 220 V.
448
Table 9.4 Rating (200 V Class)
2169
HD1
37
*1
ND1
45
*2
HD1
50
*1
ND1
60
*2
HD1 (AC)
136
HD1 (DC)
167
ND1 (AC)
164
ND1 (DC)
202
HD1
55.3
*4
ND1
64.4
*5
HD1
145
ND1
169
• HD: 150% of the rated output current for 60 seconds
• ND: 110% of the rated output current for 60 seconds
Note:
Derating may be necessary for applications that start and stop frequently.
HD1: 5 kHz without derating the drive capacity.
ND: 2 kHz without derating the drive capacity.
Derate the drive capacity to use values to 10 kHz maximum.
Three-phase 200 V to 240 V
Note:
The maximum output voltage is proportional to the input voltage.
• Advanced Open Loop Vector Control (AOLV) and EZ Open Loop Vector Control
(EZOLV): 120 Hz
• Closed Loop V/f Control (CL-V/f), Closed Loop Vector Control (CLV), Advanced Open
Loop Vector Control for PM (AOLV/PM), and Closed Loop Vector Control for PM
(CLV/PM): 400 Hz
• V/f Control (V/f), Open Loop Vector Control (OLV), and Open Loop Vector Control for
PM (OLV/PM): 590 Hz
Standard internal characteristics
External options
Factory option
• Models 2xxxB: There is a category C3 EMC filter in the drive.
• Models 2xxxC: There is a category C2 EMC filter in the drive.
• Three-phase AC power supply 200 V to 240 V at 50/60 Hz
• DC power supply 270 V to 340 V
±5%
HD1
56.5
ND1
68.2
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
2211
2257
45
55
55
75
60
75
75
100
164
200
202
245
200
271
245
332
68.6
81.9
80.4
97.9
180
215
211
257
68.2
83.1
83.1
113
2313
2360
75
90
90
110
100
125
125
150
271
324
332
397
324
394
397
483
108
132
119
137
283
346
313
360
113
135
135
164
2415
110
-
150
-
394
483
-
-
158
-
415
-
164
-

Hide quick links: