E4: Motor 2 Parameters - YASKAWA GA700 Technical Manual

Hide thumbs Also See for GA700:
Table of Contents

Advertisement

E3-11: Motor 2 Mid Point B Frequency
No.
Name
(Hex.)
E3-11
Motor 2 Mid Point B
Frequency
(0345)
Expert
Note:
• Set this parameter to 0.0 to disable the function.
• When you initialize the drive, this parameter is reset to the default value.
E3-12: Motor 2 Mid Point B Voltage
No.
Name
(Hex.)
E3-12
Motor 2 Mid Point B
Voltage
(0346)
Expert
Note:
• Set this parameter to 0.0 to disable the function.
• When you initialize the drive, this parameter is reset to the default value.
• The setting value changes automatically when you do Auto-Tuning (rotational and stationary 1 or 2).
E3-13: Motor 2 Base Voltage
No.
Name
(Hex.)
E3-13
Motor 2 Base Voltage
(0347)
Expert
Note:
• When you initialize the drive, this parameter is reset to the default value.
• The setting value changes automatically when you do Auto-Tuning (rotational and stationary 1 or 2).

E4: Motor 2 Parameters

E4 parameters [Motor 2 Parameters] set induction motor data. To switch drive operation from one motor to a
different motor, configure motor 2.
Auto-Tuning automatically sets the E4 parameters to the best values for the application. If you cannot do Auto-
Tuning, set the E4 parameters manually.
Note:
E3-xx and E4-xx are available when H1-xx = 16 [MFDI Function Select = Motor 2 Selection].
E4-01: Motor 2 Rated Current
No.
Name
(Hex.)
E4-01
Motor 2 Rated
Current
(0321)
Note:
• If E4-01 ≤ E4-03 [Motor 2 Rated No-Load Current], the drive will detect oPE02 [Parameter Range Setting Error] will be detected.
• The default settings and setting ranges are in these units:
–0.01 A: 2004 to 2042, 4002 to 4023
–0.1 A: 2056 to 2415, 4031 to 4675
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets a middle output frequency for the motor 2 V/f pattern. Set this
parameter to adjust the V/f pattern for the constant output range. Usually it
is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a middle output voltage for the motor 2 V/f pattern. Set this parameter
to adjust the V/f pattern for the constant output range. Usually it is not
necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the base voltage for the motor 2 V/f pattern. Set this parameter to adjust
the V/f pattern for the constant output range. Usually it is not necessary to
change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated current for motor 2 in amps.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.6 E: Motor Parameters
Default
(Range)
0.0 Hz
(0.0 - E3-04)
Default
(Range)
0.0 V
(200 V Class: 0.0 -
255.0 V, 400 V Class:
0.0 - 510.0 V)
Default
(Range)
0.0 V
(200 V Class: 0.0 -
255.0 V, 400 V Class:
0.0 - 510.0 V)
Default
(Range)
Determined by o2-04
and C6-01
(10% to 200% of the
drive rated current)
811
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents