YASKAWA GA700 Technical Manual page 804

Hide thumbs Also See for GA700:
Table of Contents

Advertisement

11.6 E: Motor Parameters
HD: 2004 - 2021, 4002 - 4012
ND: 2004 - 2018, 4002 - 4009
D : High Freq, 60 Hz base, 120 Hz max
Use this constant output pattern to rotate motors at more than 60 Hz. Output voltage is constant when you operate
at more than 60 Hz.
Note:
The voltage values in the figures are for 200 V class drives. Multiply the values by 2 for 400 V class drives.
HD: 2004 - 2021, 4002 - 4012
ND: 2004 - 2018, 4002 - 4009
E : High Freq, 60 Hz base, 180 Hz max
Use this constant output pattern to rotate motors at more than 60 Hz. Output voltage is constant when you operate
at more than 60 Hz.
Note:
The voltage values in the figures are for 200 V class drives. Multiply the values by 2 for 400 V class drives.
HD: 2004 - 2021, 4002 - 4012
ND: 2004 - 2018, 4002 - 4009
F : Custom
Set E1-04 to E1-13 [V/f Pattern for Motor 1] to set the values for this custom pattern.
The default settings are the same as setting value 1 [Const Trq, 60Hz base, 60Hz max].
E1-04: Maximum Output Frequency
No.
Name
(Hex.)
E1-04
Maximum Output
Frequency
(0303)
804
HD: 2030 - 2211, 4018 - 4103
ND: 2021 - 2169, 4012 - 4089
HD: 2030 - 2211, 4018 - 4103
ND: 2021 - 2169, 4012 - 4089
HD: 2030 - 2211, 4018 - 4103
ND: 2021 - 2169, 4012 - 4089
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum output frequency for the V/f pattern.
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
HD: 2257 - 2415, 4140 - 4675
HD: 2257 - 2415, 4140 - 4675
HD: 2257 - 2415, 4140 - 4675
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
ND: 2211 - 2415, 4103 - 4675
ND: 2211 - 2415, 4103 - 4675
ND: 2211 - 2415, 4103 - 4675
Default
(Range)
Determined by A1-02
and E5-01
(Determined by A1-
02 and E5-01)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents