U2: Fault Trace - YASKAWA GA700 Technical Manual

Hide thumbs Also See for GA700:
Table of Contents

Advertisement

No.
Name
(Hex.)
U1-17
DI-A3 Input Status
(0058)
U1-18
oPE Fault
Parameter
(0061)
U1-19
MEMOBUS/
Modbus Error
(0066)
Code
U1-21
AI-A3 Term V1
Level
(0077)
U1-22
AI-A3 Term V2
Level
(072A)
U1-23
AI-A3 Term V3
Level
(072B)
U1-24
Input Pulse
Monitor
(007D)
U1-25
SoftwareNumber
Flash
(004D)
U1-26
SoftwareNumber
ROM
(005B)
U1-50
Virtual Analog
Input
(1199)
Expert
U1-91
Output Voltage
(154E)
Expert

U2: Fault Trace

No.
Name
(Hex.)
U2-01
Current Fault
(0080)
U2-02
Previous Fault
(0081)
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Shows the reference value input from DI-A3 option.
Shows the input signal for DI-A3 in hexadecimal as set in F3-01
[Digital Input Function Selection].
3FFFF: Set (1 bit) + Sign (1 bit) + 16 bit
V/f
CL-V/f
OLV
CLV
AOLV
Shows the parameter number that caused the oPE02 [Parameter
Range Setting Error] or oPE08 [Parameter Selection Error].
V/f
CL-V/f
OLV
CLV
AOLV
Shows the contents of the MEMOBUS/Modbus communication
error where 1 = (error) and 0 = (no error).
For example, U1-19 shows "00000001" when a CRC error occurs.
bit 0 : CRC Error
bit 1 : Data Length Error
bit 2 : Not used (normal value of 0).
bit 3 : Parity Error
bit 4 : Overrun Error
bit 5 : Framing Error
bit 6 : Timed Out
bit 7 : Not used (normal value of 0).
V/f
CL-V/f
OLV
CLV
AOLV
Shows the analog reference of terminal V1 on analog input option
card AI-A3.
Unit: 0.1%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the analog reference of terminal V2 on analog input option
card AI-A3.
Unit: 0.1%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the analog reference of terminal V3 on analog input option
card AI-A3.
Unit: 0.1%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the frequency to pulse train input terminal RP.
Unit: 1 Hz
V/f
CL-V/f
OLV
CLV
AOLV
Shows the FLASH ID.
V/f
CL-V/f
OLV
CLV
AOLV
Shows the ROM ID.
V/f
CL-V/f
OLV
CLV
AOLV
Shows the virtual analog input value.
V/f
CL-V/f
OLV
CLV
AOLV
Shows the drive internal output voltage reference.
Unit: 0.1 V
Description
V/f
CL-V/f
OLV
CLV
AOLV
Shows the fault that the drive has when viewing the monitor.
V/f
CL-V/f
OLV
CLV
AOLV
Shows the fault that occurred most recently.
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
10.17 U: Monitors
MFAO Signal
Ref.
Level
No signal output
-
available
No signal output
-
available
No signal output
-
available
10 V = 100% (-10
-
V to +10 V)
10 V = 100% (-10
-
V to +10 V)
10 V = 100% (-10
-
V to +10 V)
Determined by H6-
-
02
No signal output
-
available
No signal output
-
available
Determined by H7-
-
40
200 V class: 10 V
-
= 200 Vrms
400 V class: 10 V
= 400 Vrms
MFAO Signal
Ref.
Level
No signal output
-
available
No signal output
-
available
601
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents