U5: PID Monitors

No.
Name
(Hex.)
U5-01
PID Feedback
(0057)
U5-02
PID Input
(0063)
U5-03
PID Output
(0064)
U5-04
PID Setpoint
(0065)
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Shows the operation signal (register 0001H) sent to the drive from
MEMOBUS/Modbus communications as a 4-digit hexadecimal
number. The keypad shows the operation signal as specified by
these rules:
bit 0 : Forward run/Stop
bit 1 : Reverse run/Stop
bit 2 : External fault
bit 3 : Fault Reset
bit 4 : Multi-function input 1
bit 5 : Multi-function input 2
bit 6 : Multi-function input 3
bit 7 : Multi-function input 4
bit 8 : Multi-function input 5
bit 9 : Multi-function input 6
bit A : Multi-function input 7
bit B : Multi-function input 8
bit C : Not used (normal value of 0).
bit D : Not used (normal value of 0).
bit E : Not used (normal value of 0).
bit F : Not used (normal value of 0).
V/f
CL-V/f
OLV
CLV
AOLV
Shows the lower 4 digits of the drive run count.
Note:
The drive run count appears as an 8-digit number. The upper 4
digits of U4-25 [Number of Runs(High)] and the lower 4 digits
of U4-24 appears.
V/f
CL-V/f
OLV
CLV
AOLV
Shows the lower 4 digits of the drive run count.
Note:
The keypad shows the drive run count in 8 digits. Monitor U4-25
shows the upper 4 digits and U4-24 [Number of Runs (Low)]
shows the lower 4 digits.
V/f
CL-V/f
OLV
CLV
AOLV
Displays the torque reference given to the drive via a serial
communication option card or via MEMOBUS/Modbus
communications as a decimal number.
Unit: 0.1%
Description
V/f
CL-V/f
OLV
CLV
AOLV
Shows the PID control feedback value. Parameter b5-20 [PID Unit
Selection] sets the display units.
Unit: 0.01%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the change between the PID setpoint and PID feedback (the
quantity of PID input) as a percentage of the maximum output
frequency.
Unit: 0.01%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the PID control output as a percentage of the maximum
output frequency.
Unit: 0.01%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the PID setpoint. Parameter b5-20 [PID Unit Selection] sets
the display units.
Unit: 0.01%
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
10.17 U: Monitors
MFAO Signal
Ref.
Level
No signal output
-
available
No signal output
-
available
No signal output
-
available
No signal output
-
available
MFAO Signal
Ref.
Level
10 V: Maximum
-
frequency (-10 V
to +10 V)
10 V: Maximum
-
frequency (-10 V
to +10 V)
10 V: Maximum
-
frequency (-10 V
to +10 V)
10 V: Maximum
-
frequency (-10 V
to +10 V)