YASKAWA GA700 Technical Manual page 509

Hide thumbs Also See for GA700:
Table of Contents

Advertisement

No.
Name
(Hex.)
b5-39
PID User Unit
Display Digits
(01FF)
b5-40
Frequency
Reference Monitor
(017F)
@PID
b5-47
PID Trim Mode
Output Reverse Sel Sets reverse motor rotation when the PID control output is negative.
(017D)
b5-53
PID Integrator
Ramp Limit
(0B8F)
RUN
b5-54
PID Softstarter
Cancel Selection
(0BB7)
b5-55
PID Feedback
Monitor Selection
(0BE1)
b5-56
PID Feedback
Monitor Gain
(0BE2)
b5-57
PID Feedback
Monitor Bias
(11DD)
b5-58 to b5-
PID Setpoints 2 to
60
4
(1182 -
1184)
RUN
b5-61
PID Trim Mode
Lower Limit Sel
(119A)
b5-62
PID Trim Mode
Lower Limit Value Sets the lower limit of the PID frequency reference trim as a
(119B)
b5-63
PID Differential
FB Monitor Sel
(119C)
b5-64
PID Differential
FB Monitor Gain
(119D)
b5-65
PID Differential
FB Monitor Bias
(119F)
b5-66
PID Feedback
Monitor Level
(11DE)
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of digits to set and show the PID setpoint.
0 : No Decimal Places (XXXXX)
1 : One Decimal Places (XXXX.X)
2 : Two Decimal Places (XXX.XX)
3 : Three Decimal Places (XX.XXX)
V/f
CL-V/f
OLV
CLV
AOLV
Sets the contents for monitor U1-01 [Frequency Reference] in PID
control.
0 : U1-01 Includes PID Output
1 : U1-01 Excludes PID Output
V/f
CL-V/f
OLV
CLV
AOLV
0 : Lower Limit is Zero
1 : Negative Output Accepted
V/f
CL-V/f
OLV
CLV
AOLV
Sets the responsiveness of PID control when the PID feedback
changes quickly.
V/f
CL-V/f
OLV
CLV
AOLV
Sets how the soft-starter responds to PID input/output.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the monitor for PID Feedback (Ux-xx).
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for the monitor specified in b5-55 [PID Feedback
Monitor Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the bias for the monitor specified in b5-55 [PID Feedback
Monitor Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the PID setpoint when H1-xx = 3E or 3F [MFDI Function
Select = PID Setpoint Selection 1/2]. This value is a percentage
where E1-04 [Maximum Output Frequency] setting = a setting value
of 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that adjusts the PID output in relation to the
frequency reference.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
percentage where E1-04 [Maximum Output Frequency] setting = a
setting value of 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the monitor for PID Differential Feedback (Ux-xx).
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for the monitor specified in b5-63 [PID Differential
FB Monitor Sel].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the bias for the monitor specified in b5-63 [PID Differential FB
Monitor Sel].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the signal level for the monitor specified in b5-55 [PID
Feedback Monitor Selection].
0 : Absolute
1 : Bi-directional (+/-)
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
10.5 b: Application
Default
Ref.
(Range)
Determined by b5-
735
20
(0 - 3)
0
735
(0, 1)
1
735
(0, 1)
0.0 Hz
736
(0.0 - 10.0 Hz)
0
736
(0, 1)
000
736
(000 - 999)
1.00
736
(0.00 - 10.00)
0.00
737
(-10.00 - +10.00)
0.00%
737
(0.00 - 100.00%)
0
737
(0, 1)
0.00%
737
(0.00 - 100.00%)
000
738
(000 - 999)
1.00
738
(0.00 - 10.00)
0.00
738
(-10.00 - +10.00)
0
738
(0, 1)
509
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents