YASKAWA GA700 Technical Manual page 532

Hide thumbs Also See for GA700:
Table of Contents

Advertisement

10.9 F: Options
No.
Name
(Hex.)
F1-13
Encoder 1 Gear
Teeth 2
(038C)
F1-14
Encoder Open-
Circuit Detect
(038D)
Time
F1-18
Deviation 3
Detection Selection Sets the number of rotations necessary to detect conditions that
(03AD)
F1-19
Deviation 4
Detection Selection Sets the number of pulses necessary to cause dv4 [Inversion
(03AE)
F1-20
Encoder 1 PCB
Disconnect Detect Sets the function that enables and disables detection of a
(03B4)
F1-21
Encoder 1 Signal
Selection
(03BC)
F1-30
Motor 2 Encoder
PCB Port Select
(03AA)
F1-31
Encoder 2 Pulse
Count (PPR)
(03B0)
F1-32
Encoder 2 Rotation
Selection
(03B1)
F1-33
Encoder 2 Gear
Teeth 1
(03B2)
F1-34
Encoder 2 Gear
Teeth 2
(03B3)
F1-35
Encoder 2 Pulse
Monitor Scaling
(03BE)
F1-36
Encoder 2 PCB
Disconnect Detect Sets the function that enables and disables detection of a
(03B5)
532
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of gear teeth on the load side. This parameter and
F1-12 [Encoder 1 Gear Teeth 1] set the gear ratio between the
motor and encoder.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of time that the drive must not receive a pulse signal
to cause a PGo [Encoder (PG) Feedback Loss].
Note:
Motor speed and load conditions can cause ov [Overvoltage] and
oC [Overcurrent] faults.
V/f
CL-V/f
OLV
CLV
AOLV
invert the torque reference and rate of acceleration and cause dv3
[Inversion Detection].
V/f
CL-V/f
OLV
CLV
AOLV
Prevention Detection].
V/f
CL-V/f
OLV
CLV
AOLV
disconnected encoder connection cable to cause PGoH [Encoder
(PG) Hardware Fault].
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of channels for the signal to the encoder option
card.
0 : A Pulse Detection
1 : AB Pulse Detection
V/f
CL-V/f
OLV
CLV
AOLV
Sets the drive port to install the motor 2 encoder option card.
0 : CN5-C
1 : CN5-B
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of output pulses for each motor revolution for
motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the output sequence for the A and B pulses from the encoder
for motor 2. This parameter assumes that the motor is operating in
the forward direction.
0 : Pulse A leads in FWD Direction
1 : Pulse B leads in FWD Direction
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of gear teeth on the motor side for motor 2. This
parameter and F1-34 [Encoder 2 Gear Teeth 2] set the gear ratio
between the motor and encoder.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of gear teeth on the load side for motor 2. This
parameter and F1-33 [Encoder 2 Gear Teeth 1] set the gear ratio
between the motor and encoder.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the ratio between the pulse input and the pulse output of the
encoder as a 3-digit number for motor 2. The first digit is the
numerator and the second and third digits set the denominator.
The dividing ratio = (1 + x)/yz when the setting value is a 3-digit
value (xyz).
V/f
CL-V/f
OLV
CLV
AOLV
disconnected encoder connection cable to cause PGoH [Encoder
(PG) Hardware Fault] for motor 2.
0 : Disabled
1 : Enabled
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
Ref.
(Range)
0
824
(0 - 1000)
2.0 s
824
(0.0 - 10.0 s)
10
824
(0 - 10)
128
824
(0 - 5000)
1
825
(0, 1)
0
825
(0, 1)
1
825
(0, 1)
1024 ppr
825
(1 - 60000 ppr)
0
825
(0, 1)
0
825
(0 - 1000)
0
826
(0 - 1000)
001
826
(001 - 032, 102 -
132 (1 - 1/32))
1
826
(0, 1)

Hide quick links: