D2: Reference Limits - YASKAWA GA700 Technical Manual

Hide thumbs Also See for GA700:
Table of Contents

Advertisement

d1-14: Reference 14
No.
Name
(Hex.)
d1-14
Reference 14
(028F)
RUN
Note:
• The upper limit value changes when the E1-04 [Maximum Output Frequency] and d2-01 [Frequency Reference Upper Limit] values
change.
• When A1-02 = 6, 7 [Control Method Selection = PM Advanced Open Loop Vector, PM Closed Loop Vector], the drive changes o1-03
= 1 [0.01% (100% = E1-04)].
• This parameter sets the frequency reference of Multi-Step Speed 14.
d1-15: Reference 15
No.
Name
(Hex.)
d1-15
Reference 15
(0290)
RUN
Note:
• The upper limit value changes when the E1-04 [Maximum Output Frequency] and d2-01 [Frequency Reference Upper Limit] values
change.
• When A1-02 = 6, 7 [Control Method Selection = PM Advanced Open Loop Vector, PM Closed Loop Vector], the drive changes o1-03
= 1 [0.01% (100% = E1-04)].
• This parameter sets the frequency reference of Multi-Step Speed 15.
d1-16: Reference 16
No.
Name
(Hex.)
d1-16
Reference 16
(0291)
RUN
Note:
• The upper limit value changes when the E1-04 [Maximum Output Frequency] and d2-01 [Frequency Reference Upper Limit] values
change.
• When A1-02 = 6, 7 [Control Method Selection = PM Advanced Open Loop Vector, PM Closed Loop Vector], the drive changes o1-03
= 1 [0.01% (100% = E1-04)].
• This parameter sets the frequency reference of Multi-Step Speed 16.
d1-17: Jog Reference
No.
Name
(Hex.)
d1-17
Jog Reference
(0292)
RUN
Note:
• The upper limit value changes when the E1-04 [Maximum Output Frequency] and d2-01 [Frequency Reference Upper Limit] values
change.
• When A1-02 = 6, 7 [Control Method Selection = PM Advanced Open Loop Vector, PM Closed Loop Vector], the drive changes o1-03
= 1 [0.01% (100% = E1-04)].

d2: Reference Limits

d2 parameters set the upper and lower frequency limits to control the motor speed. Apply these parameters to for
example, run the motor at low-speed due to mechanical strength concerns, or if the motor should not be run at low
speed because of lubrication issues with the gears and bearings.
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [Frequency Display
Unit Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [Frequency Display
Unit Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [Frequency Display
Unit Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the JOG frequency reference in the units from o1-03 [Frequency
Display Unit Selection]. Set H1-xx = 6 [MFDI Function Select = Jog
Reference Selection] to use the Jog frequency reference.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.5 d: References
Default
(Range)
0.00 Hz
(0.00 - 590.00 Hz)
Default
(Range)
0.00 Hz
(0.00 - 590.00 Hz)
Default
(Range)
0.00 Hz
(0.00 - 590.00 Hz)
Default
(Range)
6.00 Hz
(0.00 - 590.00 Hz)
11
781