YASKAWA GA700 Technical Manual page 891

Hide thumbs Also See for GA700:
Table of Contents

Advertisement

H2-21: Comparator 1 Lower Limit
No.
Name
(Hex.)
H2-21
Comparator 1 Lower
Limit
(1541)
Note:
Refer to H2-xx = 66 and 67 [MFDO Function Select = Comparator1 and Comparator2] for more information about the comparator
function.
H2-22: Comparator 1 Upper Limit
No.
Name
(Hex.)
H2-22
Comparator 1 Upper
Limit
(1542)
Note:
Refer to H2-xx = 66 and 67 [MFDO Function Select = Comparator1 and Comparator2] for more information about the comparator
function.
H2-23: Comparator 1 Hysteresis
No.
Name
(Hex.)
H2-23
Comparator 1
Hysteresis
(1543)
Note:
Refer to H2-xx = 66 and 67 [MFDO Function Select = Comparator1 and Comparator2] for more information about the comparator
function.
H2-24: Comparator 1 On-Delay Time
No.
Name
(Hex.)
H2-24
Comparator 1 On-
Delay Time
(1544)
Note:
Refer to H2-xx = 66 and 67 [MFDO Function Select = Comparator1 and Comparator2] for more information about the comparator
function.
H2-25: Comparator 1 Off-Delay Time
No.
Name
(Hex.)
H2-25
Comparator 1 Off-
Delay Time
(1545)
Note:
Refer to H2-xx = 66 and 67 [MFDO Function Select = Comparator1 and Comparator2] for more information about the comparator
function.
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the lower limit detection level for comparator 1 when the full scale
analog output for the monitor selected in H2-20 [Comparator 1 Monitor
Selection] is the 100% value.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the upper limit detection level for comparator 1 when the full scale
analog output for the monitor selected in H2-20 [Comparator 1 Monitor
Selection] is the 100% value.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the hysteresis level for comparator 1 when the full scale analog output
for the monitor selected in H2-20 [Comparator 1 Monitor Selection] is the
100% value.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the on-delay time for comparator 1.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the off-delay time for comparator 1.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.8 H: Terminal Functions
Default
(Range)
0.0%
(0.0 - 300.0%)
Default
(Range)
0.0%
(0.0 - 300.0%)
Default
(Range)
0.0%
(0.0 - 10.0%)
Default
(Range)
0.0 s
(0.0 - 600.0 s)
Default
(Range)
0.0 s
(0.0 - 600.0 s)
11
891