U6: Operation Status Monitors - YASKAWA GA700 Technical Manual

Hide thumbs Also See for GA700:
Table of Contents

Advertisement

10.17 U: Monitors
No.
Name
(Hex.)
U5-05
PID
DifferentialFdbk
(07D2)
U5-06
PID Fdbk-Diff PID
Fdbk
(07D3)
U5-21
Energy Save Coeff
Ki
(0872)
Expert
U5-22
Energy Save Coeff
Kt
(0873)
Expert
U5-99
PID Setpoint
Command
(1599)

U6: Operation Status Monitors

No.
Name
(Hex.)
U6-01
Iq Secondary
Current
(0051)
U6-02
Id
ExcitationCurrent
(0052)
U6-03
ASR Input
(0054)
U6-04
ASR Output
(0055)
U6-05
OutputVoltageRef:
Vq
(0059)
U6-06
OutputVoltageRef:
Vd
(005A)
610
Description
V/f
CL-V/f
OLV
CLV
AOLV
Shows the PID differential feedback value as a percentage of the
maximum output frequency.
This monitor is available after setting H3-02, H3-10, or H3-06 = 16
[MFAI Function Select = Differential PID Feedback].
Unit: 0.01%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the difference from calculating U5-05 - U5-01 [PID
DifferentialFdbk] - [PID Feedback].
Unit: 0.01%
Note:
U5-01 = U5-06 when H3-02, H3-10, or H3-06 ≠ 16 [MFAI
Function Select ≠ Differential PID Feedback].
V/f
CL-V/f
OLV
CLV
AOLV
Shows the energy-saving coefficient Ki value for PM.
Unit: 0.01
V/f
CL-V/f
OLV
CLV
AOLV
Shows the energy-saving coefficient Kt value for PM.
Unit: 0.01
V/f
CL-V/f
OLV
CLV
AOLV
Shows the PID setpoint command. Parameter b5-20 [PID Unit
Selection] sets display units.
Unit: 0.01%
Description
V/f
CL-V/f
OLV
CLV
AOLV
Shows the value calculated for the motor secondary current as a
percentage of the motor rated secondary current. (q axis)
Unit: 0.1%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the value calculated for the motor excitation current as a
percentage of the motor rated secondary current. (d axis)
Unit: 0.1%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the ASR input value as a percentage of the maximum
frequency.
Unit: 0.01%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the ASR output value as a percentage of the motor rated
secondary current.
Unit: 0.01%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the drive internal voltage reference for motor secondary
current control. (q axis)
Unit: 0.1 V
V/f
CL-V/f
OLV
CLV
AOLV
Shows the drive internal voltage reference for motor excitation
current control. (d axis)
Unit: 0.1 V
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
MFAO Signal
Ref.
Level
10 V: Maximum
-
frequency (-10 V
to +10 V)
10 V: Maximum
-
frequency (-10 V
to +10 V)
No signal output
-
available
No signal output
-
available
10 V: Maximum
-
frequency (-10 V
to +10 V)
MFAO Signal
Ref.
Level
10 V: Motor
-
secondary rated
current (-10 V to
+10 V)
10 V: Motor
-
secondary rated
current (-10 V to
+10 V)
10 V: Maximum
-
frequency (-10 V
to +10 V)
10 V: Motor
-
secondary rated
current (-10 V to
+10 V)
200 V class: 10 V
-
= 200 Vrms
400 V class: 10 V
= 400 Vrms
(-10 V to +10 V)
200 V class: 10 V
-
= 200 Vrms
400 V class: 10 V
= 400 Vrms
(-10 V to +10 V)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents