YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Model
To configure very accurate analog references at high
resolution.
• Input signal level: -10 Vdc to +10 Vdc (20 kΩ) at 4 mA to
20 mA (250 Ω)
• Input channel: 3 channels
Use a DIP switch to select voltage input or current input.
• Input resolution
– Voltage input: 13 bits (1/8192) + encoding
– Current input: 1/4096
To use analog signals to monitor the drive output frequency
and output current.
• Output resolution: 11 bits (1/2048) + encoding
• Output voltage: -10 Vdc to +10 Vdc (non-insulated)
• Output channels: 2 channels
To use digital speed references and MFDI with a maximum
16 bits of resolution.
• Input signals: Binary, 16 bits: BCD4 digits + SIGN signal
+ SET signal
Use parameters to select 6 bits, 8 bits, or 12 bits.
• Input voltage: 24 V (insulated)
• Input current: 8 mA
To output insulated digital signals and monitor the operation
status of the drive (alarm signals and detecting zero speed).
Type of output:
• Photocoupler relays: 6 channels (48 V, 50 mA maximum)
• Relay contact output: 2 channels (250 Vac at 1 A or less,
30 Vdc at 1 A or less)
This option uses the host controller over PROFIBUS-DP
communication to:
• Operate and stop the drive
• Set and view parameters
• Monitor output frequency, output current, and other
statuses
This option uses the host controller over CC-Link
communication to:
• Operate and stop the drive
• Set and view parameters
• Monitor output frequency, output current, and other
statuses
This option uses the host controller over DeviceNet
communication to:
• Operate and stop the drive
• Set and view parameters
• Monitor output frequency, output current, and other
statuses
Note:
The drive is compatible with option software versions
1114 and later.
This option uses the host controller over CANopen
communication to:
• Operate and stop the drive
• Set and view parameters
• Monitor output frequency, output current, and other
statuses
9.9 Peripheral Devices and Options
Purpose
Document No.
TOBPC73060078
TOBPC73060079
TOBPC73060080
TOBPC73060081
TOBPC73060082
SIEPC73060082
TOBPC73060083
SIEPC73060083
TOBPC73060084
SIEPC73060084
TOBPC73060085
SIEPC73060085