10.7 d: Reference Settings
No.
Name
(Hex.)
d1-09
Reference 9
(0288)
RUN
d1-10
Reference 10
(028B)
RUN
d1-11
Reference 11
(028C)
RUN
d1-12
Reference 12
(028D)
RUN
d1-13
Reference 13
(028E)
RUN
d1-14
Reference 14
(028F)
RUN
d1-15
Reference 15
(0290)
RUN
520
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [Frequency
Display Unit Selection].
Note:
o1-03 = 1 [0.01% (100% = E1-04)] when A1-02 = 6, 7 [Control
Method Selection = PM Advanced Open Loop Vector, PM Closed
Loop Vector].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [Frequency
Display Unit Selection].
Note:
o1-03 = 1 [0.01% (100% = E1-04)] when A1-02 = 6, 7 [Control
Method Selection = PM Advanced Open Loop Vector, PM Closed
Loop Vector].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [Frequency
Display Unit Selection].
Note:
o1-03 = 1 [0.01% (100% = E1-04)] when A1-02 = 6, 7 [Control
Method Selection = PM Advanced Open Loop Vector, PM Closed
Loop Vector].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [Frequency
Display Unit Selection].
Note:
o1-03 = 1 [0.01% (100% = E1-04)] when A1-02 = 6, 7 [Control
Method Selection = PM Advanced Open Loop Vector, PM Closed
Loop Vector].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [Frequency
Display Unit Selection].
Note:
o1-03 = 1 [0.01% (100% = E1-04)] when A1-02 = 6, 7 [Control
Method Selection = PM Advanced Open Loop Vector, PM Closed
Loop Vector].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [Frequency
Display Unit Selection].
Note:
o1-03 = 1 [0.01% (100% = E1-04)] when A1-02 = 6, 7 [Control
Method Selection = PM Advanced Open Loop Vector, PM Closed
Loop Vector].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency reference in the units from o1-03 [Frequency
Display Unit Selection].
Note:
o1-03 = 1 [0.01% (100% = E1-04)] when A1-02 = 6, 7 [Control
Method Selection = PM Advanced Open Loop Vector, PM Closed
Loop Vector].
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
Ref.
(Range)
0.00 Hz
779
(0.00 - 590.00 Hz)
0.00 Hz
780
(0.00 - 590.00 Hz)
0.00 Hz
780
(0.00 - 590.00 Hz)
0.00 Hz
780
(0.00 - 590.00 Hz)
0.00 Hz
780
(0.00 - 590.00 Hz)
0.00 Hz
781
(0.00 - 590.00 Hz)
0.00 Hz
781
(0.00 - 590.00 Hz)