YASKAWA GA700 Technical Manual page 879

Hide thumbs Also See for GA700:
Table of Contents

Advertisement

42: Run Command (2-Wire Sequence 2)
Setting
Function
42
Run Command (2-
Wire Sequence 2)
ON : Run
OFF : Stop
Note:
This function will not operate at the same time as H1-xx = 40, 41 [Forward/Reverse Run Command (2-Wire Seq)].
43: FWD/REV (2-Wire Sequence 2)
Setting
Function
43
FWD/REV (2-Wire
Sequence 2)
ON : Reverse
OFF : Forward
Note:
• You must input the Run command to rotate the motor.
• This function will not operate at the same time as H1-xx = 40, 41 [Forward/Reverse Run Command (2-Wire Seq)].
44: Add Offset Frequency 1 (d7-01)
Setting
Function
44
Add Offset
Frequency 1 (d7-01)
Note:
Refer to "d7: Offset Frequency" for more information.
45: Add Offset Frequency 2 (d7-02)
Setting
Function
45
Add Offset
Frequency 2 (d7-02)
Note:
Refer to "d7: Offset Frequency" for more information.
46: Add Offset Frequency 3 (d7-03)
Setting
Function
46
Add Offset
Frequency 3 (d7-03)
Note:
Refer to "d7: Offset Frequency" for more information.
47: Node Setup (CANopen)
Setting
Function
47
Node Setup
(CANopen)
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Run command for 2-wire sequence 2. Set this function and H1-xx = 43 [FWD/REV
Command (2-Wire Seq 2)] together.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the direction of motor rotation for 2-wire sequence 2. Set this function and H1-xx = 42 [Run
Command (2-Wire Sequence 2)] together.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to add the offset frequency set in d7-01 [Offset Frequency 1] to the frequency
reference when the terminal activates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to add the offset frequency set in d7-02 [Offset Frequency 2] to the frequency
reference when the terminal activates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to add the offset frequency set in d7-03 [Offset Frequency 3] to the frequency
reference when the terminal activates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function in CANopen communications to start the Node Setup function to set the drive
node address from the host controller.
11.8 H: Terminal Functions
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11