No.
H2-01
H2-02
H2-03
Refer to
Table 11.65
to set H2-xx [MFDO Function Select].
Setting Value
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
*1
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
*1
Inverse output is not available.
*2
You cannot set this parameter on models 2169 to 2415 and 4089 to 4675.
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Table 11.64 MFDO Terminals Default Function Settings
Name
Term M1-M2 Function Selection
Term M3-M4 Function Selection
Terminal M5-M6 Function Select
Table 11.65 MFDO Setting Value
Function
During Run
Zero Speed
Speed Agree 1
User-Set Speed Agree 1
Frequency Detection 1
Frequency Detection 2
Drive Ready
DC Bus Undervoltage
During Baseblock (N.O.)
Frequency Reference from
Keypad
Run Command from Keypad
Torque Detection 1 (N.O.)
Frequency Reference Loss
Braking Resistor Fault
Fault
Not Used
Alarm
Fault Reset Command Active
Timer Output
Speed Agree 2
User-Set Speed Agree 2
Frequency Detection 3
Frequency Detection 4
Torque Detection 1 (N.C.)
Torque Detection 2 (N.O.)
Torque Detection 2 (N.C.)
During Reverse
During Baseblock (N.C.)
Motor 2 Selected
During Regeneration
Executing Auto-Restart
Motor Overload Alarm (oL1)
Drive Overheat Pre-Alarm (oH)
Safe Torque OFF
11.8 H: Terminal Functions
Default Setting
0
1
2
Setting Value
Mechanical Weakening
22
Detection
2F
Maintenance Notification
30
During Torque Limit
31
During Speed Limit
32
In Speed Limit During Trq Ctrl
33
Zero Servo Complete
37
During Frequency Output
38
Drive Enabled
39
Watt Hour Pulse Output
3C
LOCAL Control Selected
3D
During Speed Search
3E
PID Feedback Low
3F
PID Feedback High
4A
During KEB Ride-Thru
4B
During Short Circuit Braking
4C
During Fast Stop
4D
oH Pre-Alarm Reduction Limit
4E
Braking Transistor Fault (rr)
*2
4F
Braking Resistor Overheat (rH)
*2
60
Internal Cooling Fan Failure
Pole Position Detection
61
Complete
62
Modbus Reg 1 Status Satisfied
63
Modbus Reg 2 Status Satisfied
65
Standby Output
66
Comparator1
67
Comparator2
69
External Power 24V Supply
90 to 93
DWEZ Digital Output 1 to 4
DWEZ Extended Digital Output
A0 to A7
1 to 8
Inverse output of 0 to A7
Sets an inverse output of the
function for the MFDO. Put a 1
100 to 1A7
at the front of the function
setting to set inverse output. For
example, set 138 for inverse
output of 38 [Drive Enabled].
Function
During Run
Zero Speed
Speed Agree 1
Function