YASKAWA GA700 Technical Manual page 587

Hide thumbs Also See for GA700:
Table of Contents

Advertisement

No.
Name
(Hex.)
o1-38
LCD Backlight
Off-Delay
(11BB)
RUN
o1-39
Show Initial Setup
Screen
(11BC)
RUN
o1-40
Home Screen
Display Selection
(11BD)
RUN
o1-41
1st Monitor Area
Selection
(11C1)
RUN
o1-42
1st Monitor Area
Setting
(11C2)
RUN
o1-43
2nd Monitor Area
Selection
(11C3)
RUN
o1-44
2nd Monitor Area
Setting
(11C4)
RUN
o1-45
3rd Monitor Area
Selection
(11C5)
RUN
o1-46
3rd Monitor Area
Setting
(11C6)
RUN
o1-47
Trend Plot 1 Scale
Minimum Value
(11C7)
RUN
o1-48
Trend Plot 1 Scale
Maximum Value
(11C8)
RUN
o1-49
Trend Plot 2 Scale
Minimum Value
(11C9)
RUN
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time until the LCD backlight automatically turns off.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to show the LCD keypad initial setup screen each
time the drive is energized. This parameter is only available when
using an LCD keypad.
0 : No
1 : Yes
V/f
CL-V/f
OLV
CLV
AOLV
Sets the monitor display mode for the Home screen. This parameter
is only available when using an LCD keypad.
0 : Custom Monitor
1 : Bar Graph
2 : Analog Gauge
3 : Trend Plot
V/f
CL-V/f
OLV
CLV
AOLV
Sets the horizontal axis used to show the monitor that was set in o1-
24 [Custom Monitor 1] as a bar graph. This parameter is only
available with an LCD keypad.
0 : +/- Area ( - o1-42 ~ o1-42 )
1 : + Area ( 0 ~ o1-42 )
2 : - Area ( - o1-42 ~ 0 )
V/f
CL-V/f
OLV
CLV
AOLV
Sets the horizontal axis value used to display the monitor that was
set in o1-24 [Custom Monitor 1] as a bar graph. This parameter is
only available with an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the horizontal axis used to show the monitor that was set in o1-
25 as a bar graph. This parameter is only available with an LCD
keypad.
0 : +/- Area ( - o1-44 ~ o1-44 )
1 : + Area ( 0 ~ o1-44 )
2 : - Area ( - o1-44 ~ 0 )
V/f
CL-V/f
OLV
CLV
AOLV
Sets the horizontal axis value used to display the monitor that was
set in o1-25 [Custom Monitor 2] as a bar graph. This parameter is
only available with an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the horizontal axis used to show the monitor that was set in o1-
26 as a bar graph. This parameter is only available with an LCD
keypad.
0 : +/- Area ( - o1-46 ~ o1-46 )
1 : + Area ( 0 ~ o1-46 )
2 : - Area ( - o1-46 ~ 0 )
V/f
CL-V/f
OLV
CLV
AOLV
Sets the horizontal axis value used to display the monitor that was
set in o1-26 [Custom Monitor 3] as a bar graph. This parameter is
only available with an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum value for the vertical axis used to display the
monitor that was set in o1-24[Custom Monitor 1] as a trend plot.
This parameter is only available with an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum value for the vertical axis used to display the
monitor that was set in o1-24 o1-24 [Custom Monitor 1] as a trend
plot. This parameter is only available with an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum value for the vertical axis used to display the
monitor that was set in o1-25[Custom Monitor 2] as a trend plot.
This parameter is only available with an LCD keypad.
10.13 o: Keypad-Related Settings
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
Ref.
(Range)
60 s
1014
(10 - 300 s)
1
1014
(0, 1)
0
1015
(0 - 3)
0
1015
(0 - 2)
100.0%
1015
(0.0 - 100.0%)
0
1015
(0 - 2)
100.0%
1016
(0.0 - 100.0%)
0
1016
(0 - 2)
100.0%
1016
(0.0 - 100.0%)
100%
1016
(-300 - +300%)
100.0%
1016
(-99.9 - +300.0%)
100%
1016
(-300 - +300%)
587