YASKAWA GA700 Technical Manual page 672

Hide thumbs Also See for GA700:
Table of Contents

Advertisement

10.22 Parameters Changed by PM Motor Code Selection
Table 10.35 SST4 Series Motor Code Setting for Specification of 400 V at 1150 min
No.
Name
PM Motor Code
Selection
Voltage Class
E5-01
Capacity
Motor Rotation
Speed
E5-02 PM Motor Rated
Power (kW)
PM Motor Rated
E5-03
Current (FLA)
PM Motor Pole
E5-04
Count
PM Motor
E5-05
Resistance (ohms/
phase)
PM d-axis
E5-06
Inductance (mH/
phase)
PM q-axis
E5-07
Inductance (mH/
phase)
PM Back-EMF
E5-09
Vpeak (mV/(rad/
s))
PM Motor Induced
E5-24
Voltage Constant 2
(Ke)
E1-04 Maximum Output
Frequency
E1-05 Maximum Output
Voltage
E1-06 Base Frequency
Minimum Output
E1-09
Frequency
C5-17 Motor Inertia
L3-24
Motor Accel Time
for Inertia Cal
*1
n5-02 Motor
Acceleration Time
d-Axis Cur
n8-49
forHighEfficiency
Cont
*1
Default settings vary depending on the setting of o2-04 [Drive Model Selection].
672
Unit
-
2445
2446
V
400
400
kW
55
-1
min
1150
1150
kW
55.00
75.00
A
93.1
128.1
-
6
Ω
0.051
0.032
mH
3.99
2.97
mH
5.39
3.90
mVs/rad
853.8
829.6
mV/(r/
0.0
0.0
min)
Hz
57.5
57.5
V
380.0
380.0
Hz
57.5
57.5
Hz
2.9
2.9
kgm
2
0.55
0.82
s
0.145
0.159
s
0.145
0.159
%
-15.9
-15.7
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Motor Code (setting value of E5-01)
2447
2448
400
400
75
90
110
1150
1150
90.00
110.00
153.1
186.5
6
6
0.026
0.015
2.44
1.87
3.23
2.46
835.6
833.4
0.0
0.0
57.5
57.5
380.0
380.0
57.5
57.5
2.9
2.9
0.96
1.60
0.155
0.211
0.155
0.211
-15.7
-14.7
-1
(r/min)
2449
244A
400
400
132
160
1150
1150
132.00
160.00
221.9
269.8
6
6
6
0.012
0.009
1.49
1.41
2.08
1.88
848.6
889.1
0.0
0.0
57.5
57.5
380.0
380.0
57.5
57.5
2.9
2.9
1.95
2.82
0.214
0.256
0.214
0.256
-16.5
-14.1
244C
400
200
1150
200.00
336.5
6
0.007
1.22
1.51
915.0
0.0
57.5
380.0
57.5
2.9
3.70
0.268
0.268
-10.3

Hide quick links: