No.
Name
(Hex.)
U6-07
q-Axis ACR
Output
(005F)
Expert
U6-08
d-Axis ACR
Output
(0060)
Expert
U6-09
AdvPhase Compen
Δθ
(07C0)
Expert
U6-10
ContAxisDeviation
Δθ
(07C1)
Expert
U6-13
MagPolePosition
(Enc)
(07CA)
Expert
U6-14
MagPolePosition
(Obs)
(07CB)
Expert
U6-17
Energy Save Coeff
(07D1)
Expert
U6-18
Enc 1 Pulse
Counter
(07CD)
U6-19
Enc 2 Pulse
Counter
(07E5)
U6-20
UP/DOWN 2 Bias
Value
(07D4)
U6-21
Offset Frequency
(07D5)
U6-22
ZeroServo Pulse
Move
(0062)
U6-25
ASR Output Level
(006B)
Expert
U6-26
Feed Fwd Cont
Output
(006C)
Expert
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Shows the output value for current control related to motor
secondary current. (q axis)
Unit: 0.1%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the output value for current control related to motor
excitation current. (d axis)
Unit: 0.1%
V/f
CL-V/f
OLV
CLV
AOLV
Displays the data on forward phase compensation for the calculation
results of the amount of control axis deviation.
Unit: 1 °
V/f
CL-V/f
OLV
CLV
AOLV
Shows the deviation between the γδ-Axis used for motor control and
the dq-Axis.
Unit: 0.1 °
V/f
CL-V/f
OLV
CLV
AOLV
Shows the value of the flux position detection.
Unit: 0.1 °
V/f
CL-V/f
OLV
CLV
AOLV
Shows the value of the flux position estimation.
Unit: 0.1 °
V/f
CL-V/f
OLV
CLV
AOLV
Shows the total time of direction of motor rotation detections for
Speed Estimation Speed Searches. This value adjusts b3-26
[Direction Determination Level].
Note:
Upper limit is +32767 and lower limit is -32767.
V/f
CL-V/f
OLV
CLV
AOLV
Shows the number of pulses for speed detection (PG1).
Unit: 1 pulse
V/f
CL-V/f
OLV
CLV
AOLV
Shows the number of pulses for speed detection (PG2).
Unit: 1 pulse
V/f
CL-V/f
OLV
CLV
AOLV
Shows the bias value used to adjust the frequency reference.
Unit: 0.1%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the total value of d7-01 to d7-03 [Offset Frequency 1 to 3]
selected with Add Offset Frequency 1 to 3 [H1-xx = 44 to 46].
Unit: 0.1%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the distance that the rotor moved from its last position when
Zero Servo is available. The value shown in this monitor = 4 X [No.
of PG pulses].
Unit: 1 pulse
V/f
CL-V/f
OLV
CLV
AOLV
Shows the primary delay filter input value of the ASR (speed
control loop).
Unit: 0.01%
V/f
CL-V/f
OLV
CLV
AOLV
Shows the Feed Forward control output.
Unit: 0.01%
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
10.17 U: Monitors
MFAO Signal
Ref.
Level
200 V class: 10 V
-
= 200 Vrms
400 V class: 10 V
= 400 Vrms
(-10 V to +10 V)
200 V class: 10 V
-
= 200 Vrms
400 V class: 10 V
= 400 Vrms
(-10 V to +10 V)
10 V: 180° (-10 V
-
to +10 V)
10 V: 180° (-10 V
-
to +10 V)
10 V: 180° (-10 V
-
to +10 V)
10 V: 180 ° (-10 V
-
to +10 V)
No signal output
-
available
10 V: 65536
-
10 V: 65536
-
10 V: Maximum
-
Frequency
10 V: Maximum
-
Frequency
10 V: Number of
-
pulses per
revolution (-10 V
to +10 V)
10 V: Motor
-
secondary rated
current (-10 V to
+10 V)
10 V: Motor
-
secondary rated
current (-10 V to
+10 V)
611
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents