No.
Name
(Hex.)
F7-14
Duplex Mode
Selection
(03F2)
F7-15
Communication
Speed Selection
(03F3)
F7-16
Timeout Value
(03F4)
F7-17
EtherNet/IP Speed
Scaling Factor
(03F5)
F7-18
EtherNet/IP
Current Scale
(03F6)
Factor
F7-19
EtherNet/IP Torque
Scale Factor
(03F7)
F7-20
EtherNet/IP Power
Scaling Factor
(03F8)
F7-21
EtherNet/IP
Voltage Scale
(03F9)
Factor
F7-22
EtherNet/IP Time
Scaling
(03FA)
F7-23 to
Dynamic Out
F7-27
Param 1 to 10 for
CommCard
(03FB -
03FF)
F7-28 to
F7-32
(0370 -
0374)
F7-33 to
Dynamic In Param
F7-42
1 to 10 for
CommCard
(0375 -
037E)
F7-60
PZD1 Write
(Control Word)
(0780)
F7-61
PZD2 Write
(Frequency
(0781)
Reference)
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the duplex mode setting method.
0 : Half/Half
1 : Auto/Auto
2 : Full/Full
3 : Half/Auto
4 : Half/Full
5 : Auto/Half
6 : Auto/Full
7 : Full/Half
8 : Full/Auto
V/f
CL-V/f
OLV
CLV
AOLV
Sets the communications speed.
10 : 10/10 Mbps
102 : 100/10 Mbps
V/f
CL-V/f
OLV
CLV
AOLV
Sets the detection time for a communications timeout.
Note:
Set this parameter to 0.0 to disable the connection timeout
function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the speed monitor in the EtherNet/IP
Class ID 2AH Object.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the output current monitor in the
EtherNet/IP Class ID 2AH Object.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the torque monitor in the EtherNet/IP
Class ID 2AH Object.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the power monitor in the EtherNet/IP
Class ID 2AH Object.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the voltage monitor in the EtherNet/IP
Class ID 2AH Object.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the scaling factor for the time monitor in the EtherNet/IP Class
ID 2AH Object.
V/f
CL-V/f
OLV
CLV
AOLV
Sets Output Assembly 116. The drive writes the values from Output
Assembly 116 to the MEMOBUS/Modbus address register that is
stored for each parameter. The drive will not write the values from
Output Assembly 116 to the registers when the MEMOBUS/
Modbus address is 0.
V/f
CL-V/f
OLV
CLV
AOLV
Sets Input Assembly 166. The drive sends the values from the
MEMOBUS/Modbus address registers stored for each parameter to
Input Assembly 166. The drive returns the default register value for
the option card when the MEMOBUS/Modbus address is 0 and the
value sent to Input Assembly 166 is not defined.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS/Modbus address for PZD1 (PPO output).
PZD1 (PPO output) functions as the STW when F7-60 = 0, 1, or 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS/Modbus address for PZD2 (PPO output).
PZD2 (PPO output) functions as the HSW when F7-61 = 0, 1, or 2.
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
10.9 F: Options
Default
Ref.
(Range)
1
856
(0 - 8)
10
856
(10, 102)
0.0 s
857
(0.0 - 30.0 s)
0
857
(-15 - +15)
0
857
(-15 - +15)
0
857
(-15 - +15)
0
857
(-15 - +15)
0
857
(-15 - +15)
0
857
(-15 - +15)
0
858
0
858
0
858
0
858
543