YASKAWA GA700 Technical Manual page 868

Hide thumbs Also See for GA700:
Table of Contents

Advertisement

11.8 H: Terminal Functions
2: External Reference 1/2 Selection
Setting
Function
2
External Reference 1/
2 Selection
Note:
When the drive is receiving a Run command, you cannot switch between reference sources.
ON : b1-15 = [Frequency Reference Selection 2], b1-16 [Run Command Selection 2]
OFF : b1-01 = [Frequency Reference Selection 1], b1-02 [Run Command Selection 1]
3: Multi-Step Speed Reference 1
Setting
Function
3
Multi-Step Speed
Reference 1
Note:
Refer to "Setting Procedures for Multi-step Speed Operation" in "d: Reference Settings" for more information.
4: Multi-Step Speed Reference 2
Setting
Function
4
Multi-Step Speed
Reference 2
Note:
Refer to "Setting Procedures for Multi-step Speed Operation" in "d: Reference Settings" for more information.
5: Multi-Step Speed Reference 3
Setting
Function
5
Multi-Step Speed
Reference 3
Note:
Refer to "Setting Procedures for Multi-step Speed Operation" in "d: Reference Settings" for more information.
6: Jog Reference Selection
Setting
Function
6
Jog Reference
Selection
7: Accel/Decel Time Selection 1
Setting
Function
7
Accel/Decel Time
Selection 1
Note:
Refer to "C1: Accel & Decel Time" for more information.
8: Baseblock Command (N.O.)
Setting
Function
8
Baseblock Command
(N.O.)
868
V/f
CL-V/f
OLV
CLV
AOLV
Sets the drive to use Run command source 1/2 or Reference command source 1/2 when in
REMOTE Mode.
V/f
CL-V/f
OLV
CLV
AOLV
Uses speed references d1-01 to d1-08 [Multi-Step Speed Reference] to set a multi-step speed
reference.
V/f
CL-V/f
OLV
CLV
AOLV
Uses speed references d1-01 to d1-08 [Multi-Step Speed Reference] to set a multi-step speed
reference.
V/f
CL-V/f
OLV
CLV
AOLV
Uses speed references d1-01 to d1-08 [Multi-Step Speed Reference] to set a multi-step speed
reference.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the drive to use the JOG Frequency Reference (JOG command) set in d1-17. The JOG
Frequency Reference (JOG command) overrides Frequency References 1 to 16 (d1-01 to d1-16).
V/f
CL-V/f
OLV
CLV
AOLV
Sets the drive to use Acceleration/Deceleration Time 1 [C1-01, C1-02] or Acceleration/
Deceleration Time 2 [C1-03, C1-04].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the command that stops drive output and coasts the motor to stop when the input is ON.
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents