4.2 European Standards
WARNING! Do not ground the main circuit bus. Failure to obey can cause death or serious injury.
Note:
• Install a fuse for each drive when operating more than one drive. If one fuse blows, replace all fuses.
• Install the external filter (system) to comply with the EMC Directive.
Refer to
Table 4.4
and
Table 4.5
Drive Model
2004
2006
2010
2012
2018
2021
2030
2042
2056
2070
2082
2110
2138
2169
2211
2257
2313
2360
2415
*1
Yaskawa recommends a fuse with a large rated current for applications with repeated loads.
244
Figure 4.3 Wiring Example for DC Power Supply Input
for the recommended fuses.
Table 4.4 Recommended Fuse (Three-Phase 200 V Class)
FWH-45B
FWH-45B
FWH-45B
FWH-50B
FWH-80B
FWH-80B
FWH-125B
FWH-150B
FWH-200B
FWH-250A
FWH-250A
FWH-300A
FWH-250A
FWH-275A
FWH-300A
FWH-350A
FWH-350A
FWH-450A
FWH-450A
FWH-600A
FWH-600A
FWH-700A
FWH-800A
FWH-1000A
FWH-1000A
FWH-1000A