YASKAWA GA700 Technical Manual page 557

Hide thumbs Also See for GA700:
Table of Contents

Advertisement

Setting
Function
E
Fault
F
Not Used
10
Alarm
11
Fault Reset
Command Active
12
Timer Output
13
Speed Agree 2
14
User-Set Speed
Agree 2
15
Frequency
Detection 3
16
Frequency
Detection 4
17
Torque Detection 1
(N.C.)
18
Torque Detection 2
(N.O.)
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the drive detects a fault.
Note:
The terminal will not turn on for CPF00 and CPF01 [Control Circuit Error] faults.
V/f
CL-V/f
OLV
CLV
AOLV
Use this setting for unused terminals or to use terminals in through mode. Also use this
setting as the PLC contact output via MEMOBUS/Modbus or the communication option.
This signal does not function if signals from the PLC are not configured.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal turns on when the drive detects a minor fault.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal turns on when the drive receives the Reset command from the control
circuit terminal, serial communications, or the communication option.
V/f
CL-V/f
OLV
CLV
AOLV
Use this setting when the drive uses the timer function as an output terminal.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the output frequency is in the range of the frequency
reference ± L4-04 [Speed Agree Detection Width (+/-)].
Note:
The drive uses the motor speed as the reference in CLV and CLV/PM.
ON : The output frequency is in the range of "frequency reference ± L4-04".
OFF : The output frequency is not in the range of "frequency reference ± L4-04".
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the output frequency is in the range of L4-03 [Speed Agree
Detect Level (+/-)] ± L4-04 [Speed Agree Detect Width (+/-)] and in the range of the
frequency reference ± L4-04.
ON : The output frequency is in the range of "L4-03 ± L4-04" and the range of frequency
reference ± L4-04.
OFF : The output frequency is not in the range of "L4-03 ± L4-04" or the in the range of
frequency reference ± L4-04.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the output frequency is higher than the setting value of
"L4-03 [Speed Agree Detect Level (+/-)] + L4-04 [Speed Agree Detect Width (+/-)]".
After the terminal deactivates, the terminal stays off until the output frequency is at the
value of L4-03.
Note:
• The detection level set with L4-03 is a signed value. The drive will only detect in one
direction.
• The drive uses the motor speed as the reference in CLV and CLV/PM.
ON : The output frequency is less than the value of L4-03 or is not higher than the value
of L4-03 + L4-04.
OFF : The output frequency is higher than the value of L4-03 + L4-04.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the output frequency is higher than the value of L4-03
[Speed Agree Detect Level (+/-)]. After the terminal activates, the terminal stays on until
the output frequency is at the value of L4-03 - L4-04.
ON : The output frequency is higher than the value of L4-03.
OFF : The output frequency is less than the value of "L4-03 - L4-04", or it is not higher
than the value of L4-03.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the drive detects overtorque or undertorque.
OFF : The output current/torque is more than the torque value set with L6-02 [Torque
Detection Level 1], or the level is less than the torque value set with L6-02 for longer
than the time set with L6-03 [Torque Detection Time 1].
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the drive detects overtorque or undertorque.
ON : The output current/torque is more than the torque value set with L6-05 [Torque
Detection Level 2], or the level is less than the torque value set with L6-05 for longer
than the time set with L6-06 [Torque Detection Time 2].
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
10.10 H: Terminal Functions
Ref.
900
900
901
901
901
901
901
902
902
903
903
10