L5: Fault Restart - YASKAWA GA700 Technical Manual

Hide thumbs Also See for GA700:
Table of Contents

Advertisement

L4-07: Speed Agree Detection Selection
No.
Name
(Hex.)
L4-07
Speed Agree
Detection Selection
(0470)
0 : No Detection during Baseblock
Detects the frequency while the drive is operating. When the drive turns off its output, it will not detect frequency.
1 : Detection Always Enabled

L5: Fault Restart

The Auto Restart function tries to keep machines operating when the drive detects a transient fault.
The drive can do a self-diagnostic check and continue the operation after a fault has occurred. If the cause of the
fault goes away, the drive does speed search and restarts. It will not stop and the drive will not record a fault
history. Use L5-02 [Fault Contact at Restart Select] to select the operation of fault relay signals during Auto
Restart operation.
Sets if the drive will do Auto Restart and the number of times the drive will try to do Auto Restart in a set time. If
the number of Auto Restart tries is more than the set value during the set time, drive output shuts off and operation
stops. If this happens, remove the cause of the fault and manually restart the drive.
DANGER! Sudden Movement Hazard. Failure to obey can cause death or serious injury. Do not use the fault restart function in
hoist or lifting applications.
The drive can do Auto Restart when these faults occur:
Note:
You can disable Auto Restart for faults if you must not restart the machine after the fault.
Fault
GF
Ground Fault
LF
Output Phase Loss
oC
Overcurrent
oH1
Heatsink Overheat
oL1
Motor Overload
oL2
Drive Overload
oL3
Overtorque Detection
1
oL4
Overtorque Detection
2
*1
Uv1 is the target for the auto restart process when L2-01 = 1, 2, 3, or 4 [Power Loss Ride Through Select = Enabled for L2-02 Time,
Enabled while CPU Power Active, Kinetic Energy Backup: L2-02, or Kinetic Energy Backup: CPU Power].
L5-01: Number of Auto-Restart Attempts
No.
Name
(Hex.)
L5-01
Number of Auto-
Restart Attempts
(049E)
The drive resets the number of Auto Restart attempts to 0 in these conditions:
• The drive operates correctly for 10 minutes after a fault restart.
• When you manually clear a fault after the drive triggers protective functions.
• When you re-energize the drive.
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
V/f
CL-V/f
OLV
CLV
Sets the condition that activates speed detection.
Table 11.73 List of Faults during which Auto Restart is Available
Parameters to
Name
Disable Auto
Restart
L5-08
-
-
L5-08
L5-07
L5-07
L5-07
L5-07
V/f
CL-V/f
OLV
CLV
Sets the number of times that the drive will try to restart.
Description
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Fault
ov
Overvoltage
PF
Input Phase Loss
rH
Braking Resistor
Overheat
rr
Dynamic Braking
Transistor Fault
STPo
Motor Step-Out
Detected
Uv1
DC Bus
Undervoltage
Description
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
11.9 L: Protection Functions
Default
(Range)
0
(0, 1)
Parameters to
Name
Disable Auto
Restart
L5-08
-
-
-
-
L5-08
*1
Default
(Range)
0
(0 - 10 times)
11