11.11 o: Keypad-Related Settings
Copies the parameter setting values saved in the keypad to a different drive.
3 : Verify (check for mismatch)
Makes sure that the parameter setting values in the drive agree with the parameters saved in the keypad.
4 : Erase (backup data of keypad)
Deletes the parameter setting values saved in the keypad.
o3-02: Copy Allowed Selection
No.
Name
(Hex.)
o3-02
Copy Allowed
Selection
(0516)
Note:
When you select [Parameter Backup] on the keypad menu screen to do the backup function, the drive automatically sets o3-02 = 1.
0 : Disabled
1 : Enabled
o3-04: Select Backup/Restore Location
No.
Name
(Hex.)
o3-04
Select Backup/
Restore Location
(0B3E)
You can use the LCD keypad to make a maximum of 4 parameter backup sets.
0 : Memory Location 1
1 : Memory Location 2
2 : Memory Location 3
3 : Memory Location 4
o3-05: Select Items to Backup/Restore
No.
Name
(Hex.)
o3-05
Select Items to
Backup/Restore
(0BDA)
0 : Standard Parameters
1 : Standard + DWEZ Parameters
Note:
• The qx-xx and rx-xx parameters appear when A1-07 = 1 or 2 [DriveWorksEZ Function Selection = DWEZ Enabled or Enabled/
Disabled wDigital Input].
• When o3-05 = 1, parameters are only restored and verified.
o3-06: Auto Parameter Backup Selection
No.
Name
(Hex.)
o3-06
Auto Parameter
Backup Selection
(0BDE)
When you connect the drive and keypad, parameters set to the drive are automatically backed up to the keypad as
specified by the setting of parameters o3-06 and o3-07.
0 : Disabled
1 : Enabled
1022
V/f
CL-V/f
OLV
CLV
AOLV
Sets the copy function when o3-01 = 1 [Copy Keypad Function Selection =
Backup (drive → keypad)].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the storage location for drive parameters when you back up and restore
parameters. This parameter is only available with an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets which parameters are backed up, restored, and referenced. This
parameter is only available with an LED keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that automatically backs up parameters. This parameter is
only available when using an LCD keypad.
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
(Range)
0
(0, 1)
Default
(Range)
0
(0 - 3)
Default
(Range)
0
(0, 1)
Default
(Range)
1