11.11 o: Keypad-Related Settings
The frequency reference changes when you enter it with the keypad. This then changes the output frequency. It is
not necessary to push
the keypad to change the frequency reference value.
o2-06: Keypad Disconnect Detection
No.
Name
(Hex.)
o2-06
Keypad Disconnect
Detection
(050A)
This parameter continues to operate if the keypad installed to the drive becomes disconnected.
This parameter is enabled in these conditions:
• When b1-02 = 0 [Run Command Selection 1 = Keypad] or b1-16 = 0 [Run Command Selection 2 = Keypad]
• In LOCAL Mode
0 : Disabled
The drive continues operation when it detects a keypad disconnection.
1 : Enabled
The drive stops operation, detects oPr [Keypad Connection Fault], and the motor coasts to stop when the drive
detects a keypad disconnection.
o2-07: Keypad RUN Direction @ Power-up
No.
Name
(Hex.)
o2-07
Keypad RUN
Direction @ Power-
(0527)
up
This parameter is enabled in these conditions:
• When b1-02 = 0 [Run Command Selection 1 = Keypad] or b1-16 = 0 [Run Command Selection 2 = Keypad]
• In LOCAL Mode
0 : Forward
1 : Reverse
o2-09: Region Code
No.
Name
(Hex.)
o2-09
Region Code
(050D)
o2-23: External 24V Powerloss Detection
No.
Name
(Hex.)
o2-23
External 24V
Powerloss Detection
(11F8)
Note:
The drive will not run when it is operating from one 24-V external power supply.
0 : Disabled
The drive does not detect the loss of the 24-V external power supply.
1 : Enabled
The keypad shows the L24v [Ext. 24-V Power Supply Lost] indicator when the drive detects the loss of the 24-V
external power supply.
1020
. The drive keeps the frequency reference for 5 seconds after you use
V/f
CL-V/f
OLV
Sets the function that stops the drive if you disconnect the keypad
connection cable from the drive or if you damage the cable while the
keypad is the Run command source.
V/f
CL-V/f
OLV
Sets the direction of motor rotation when the drive is energized and the
keypad is the Run command source.
-
V/f
CL-V/f
OLV
Sets the function to give a warning when the backup external 24 V power
supply turns off when the main circuit power supply is in operation.
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Description
CLV
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
CLV
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
Description
CLV
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
and
on
Default
(Range)
Determined by o2-09
(0, 1)
Default
(Range)
0
(0, 1)
Default
(Range)
-
Default
(Range)
0
(0, 1)

Hide quick links: