10.18 Parameters that Change from the Default Settings with A1-02 [Control Method Selection]
No.
Name
Motor
Overload
L1-01
(oL1)
Protection
Stall
L3-05
Prevention
during RUN
DC Bus
Voltage
L3-20
Adjustment
Gain
OVSuppres
L3-21
sion Accel/
Decel P Gain
Current
L3-36
Suppression
Gain@Accel
Speed Agree
L4-01
Detection
Level
Speed Agree
L4-02
Detection
Width
Speed Agree
L4-03
Detection
Level(+/-)
Speed Agree
L4-04
Detection
Width(+/-)
Carrier
L8-38
Frequency
Reduction
Carrier Freq
L8-40
Reduction
Off-Delay
PWM
Voltage
n1-15
Offset
Calibration
Frequency
o1-03
Display Unit
Selection
V/f Pattern
o1-04
Display Unit
*1
Drive models 2211 to 2415 and 4103 to 4675 use these default settings when C6-01 = 1 [Normal / Heavy Duty Selection = Normal
Duty Rating]. Drive models 2257 to 2415, 4140 to 4675 use these default settings when C6-01 = 0 [Heavy Duty Rating].
• A1-02 = 2 [Open Loop Vector]:2.00
• A1-02 = 3, 4 [Closed Loop Vector, Advanced Open Loop Vector]:0.05
*2
The default setting is 1000 ms for drive models 2110 to 2415 and 4103 to 4675.
*3
The default setting varies depending on the setting of C6-01 [Normal / Heavy Duty Selection].
*4
The setting range varies depending on the setting of E5-01 [PM Motor Code Selection] when A1-02 = 5 [Control Method Selection
= PM Open Loop Vector].
*5
The default setting varies depending on drive model and E1-03 [V/f Pattern Selection] settings.
*6
This is the value for 200 V class drives. Double the value for 400 V class drives.
*7
The maximum value within the setting range is 100.0 when A1-02 = 5 or 7 [Control Method Selection = PM Open Loop Vector or
PM Closed Loop Vector].
*8
The setting range is -100.0 to 100.0 when A1-02 = 5 or 7 [Control Method Selection = PM Open Loop Vector or PM Closed Loop
Vector].
616
Setting
Unit
Range
0 - 4
1
0 - 3
1
0.00 - 5.00
0.01
0.10 - 10.00
0.01
0.0 - 100.0
0.1
0.0 - 400.0
0.1
*7
0.0 - 20.0
0.1
-400.0 -
0.1
+400.0
*8
0.0 - 20.0
0.1
0 - 2
1
0.00 - 2.00
0.01 s
0 - 2
1
0 - 3
1
0 - 1
1
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Control Method (A1-02 Setting)
V/f
CL-V/f
(0)
(1)
1
1
1
1
1.00
1.00
1.00
1.00
10.0
10.0
0.0 Hz
0.0 Hz
2.0 Hz
2.0 Hz
0.0 Hz
0.0 Hz
2.0 Hz
2.0 Hz
*3
*3
0.50
0.50
1
1
0
0
-
-
OLV
CLV
(2)
(3)
1
1
-
-
0.30
0.30
1.00
1.00
20.0
-
0.0 Hz
0.0 Hz
2.0 Hz
2.0 Hz
0.0 Hz
0.0 Hz
2.0 Hz
2.0 Hz
*3
*3
0.50
0.50
1
1
0
0
-
0
AOLV
(4)
1
-
0.30
1.00
-
0.0 Hz
2.0 Hz
0.0 Hz
2.0 Hz
*3
0.50
2
0
0