2.13 Main Circuit Terminal Block Wiring Procedure
Screw Size
Screw Shape
M4
Slotted (-)
M5
Slotted (-)
*1
Hex socket cap
(WAF: 5 mm)
M6
Slotted (-)
Hex socket cap
M8
(WAF: 6 mm)
Hex socket cap
M10
(WAF: 8 mm)
*1
When wiring drive models 2056 and 4089 and smaller, select the correct tools for the wire gauge.
*2
Use 6.35 mm (0.25 in) bit socket holder.
*3
Use a torque wrench that can apply this torque measurement range.
Main Circuit Terminal Block Wiring Procedure
Remove the keypad and front cover before wiring the main circuit terminal block.
1.
Pull the wiring cover forward to remove it from the drive.
A - Wiring cover
2.
Put the end of a prepared wire into the terminal block.
100
Table 2.19 Recommended Wiring Tools
Adapter
Model
SF-BIT-SL
Bit
1,0X4,0-70
SF-BIT-SL
Bit
1,2X6,5-70
Bit
SF-BIT-HEX 5-50
SF-BIT-SL
Bit
1,2X6,5-70
Bit
SF-BIT-HEX 6-50
Bit
SF-BIT-HEX 8-50
Figure 2.91 Remove the Wiring Cover
Figure 2.92 Install the Electrical Wire
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Bit
Torque Driver
Model
(Tightening
Manufacturer
Torque)
TSD-M 3NM
PHOENIX
CONTACT
(1.2 - 3 N∙m)
Wire Gauge ≤
25 mm
(AWG 10):
TSD-M 3NM
PHOENIX
(1.2 - 3 N∙m)
CONTACT
Wire Gauge ≥
30 mm
(AWG 8):
PHOENIX
CONTACT
PHOENIX
CONTACT
PHOENIX
CONTACT
PHOENIX
CONTACT
Torque Wrench
-
Wire Gauge ≤
2
2
25 mm
(AWG 10):
-
Wire Gauge ≥
2
30 mm
2
(AWG 8):
-
4.1 - 4.5 N∙m
*2 *3
-
5 - 9 N∙m
*2 *3
-
3 - 3.5 N∙m
*2 *3
-
8 - 12 N∙m
*2 *3
-
12 - 14 N∙m
*2 *3