YASKAWA GA700 Technical Manual page 1029

Hide thumbs Also See for GA700:
Table of Contents

Advertisement

No.
Item
15
Encoding data
16
Row number
o5-01: Log Start/Stop Selection
No.
Name
(Hex.)
o5-01
Log Start/Stop
Selection
(1551)
RUN
0 : OFF
Stops the data log.
1 : ON
Starts the data log as specified by the sampling cycle set in o5-02 [Log Sampling Interval].
o5-02: Log Sampling Interval
No.
Name
(Hex.)
o5-02
Log Sampling
Interval
(1552)
RUN
o5-03: Log Monitor Data 1
No.
Name
(Hex.)
o5-03
Log Monitor Data 1
(1553)
RUN
Note:
Set the log data with values 101 to 999 [U1-01 to U9-99].
For example, to show U1-05 [Motor Speed], set o5-03 = 105. When it is not necessary to set data log monitors, set this parameter to
000. You cannot set U2 monitors [Fault Trace] or U3 Monitors [Fault History].
o5-04: Log Monitor Data 2
No.
Name
(Hex.)
o5-04
Log Monitor Data 2
(1554)
RUN
Note:
Set the log data with values 101 to 999 [U1-01 to U9-99].
For example, to show U1-05 [Motor Speed], set o5-04 = 105. When it is not necessary to set data log monitors, set this parameter to
000. You cannot set U2 monitors [Fault Trace] or U3 Monitors [Fault History].
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Number of
Charac
ters
4
Encoding data for log monitor data 1 through 10 (Hex.)
Bits 0 through 9 show the encoding of log monitor data 1 1 through 10. A bit value of 1
shows that the data represents a negative value. (Log monitor data 1 through 10 is absolute
value data without encoding)
Example when log monitor data 2, 5, and 8 show negative values: Bits 1, 4, and 7 have
values of 1, and the encoding data = 0010010010 (Bin.) = 0092 (Hex.)
6
Row number (Hex.) in the data log file
V/f
CL-V/f
OLV
CLV
Sets the data log function. This parameter is only available on an LCD
keypad.
V/f
CL-V/f
OLV
CLV
Sets the data log sampling cycle. This parameter is only available on an
LCD keypad.
V/f
CL-V/f
OLV
CLV
Sets the data log monitor. This parameter is only available on an LCD
keypad.
V/f
CL-V/f
OLV
CLV
Sets the data log monitor. This parameter is only available on an LCD
keypad.
11.11 o: Keypad-Related Settings
Description
Description
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
(Range)
0
(0 - 1)
Default
(Range)
1000 ms
(100 - 6000 ms)
Default
(Range)
101
(000,101 - 855)
Default
(Range)
102
(000,101 - 855)
11