Step 1. Press
.
Step 2. Press
.
Ripple Limit
Step 3. Press
. This menu toggles between on and off.
Fail Sign
In addition to the screen, the following features also let you confirm the test results:
Beep notifying that the result was "fail"
Status register (for further information, see the Programmer's Guide)

Configuring ripple limit

You must configure the ripple limit before you can use the ripple test function. You can
specify a ripple limit table for each trace, where up to 12 ripple limit bands (frequency
bands) can be configured.
Operational procedure
Follow the steps below to configure the ripple limits.
Step 1. Press
or
ripple test function.
Step 2. Press
or
test function.
Step 3. Press
to display the Analysis menu.
Step 4. Press
to display the softkeys for to the ripple test.
Ripple Limit
Step 5. Press Edit Ripple Limit to display the ripple limit table shown in Figure 11-9 on page 386,
and create or edit the bands. Note that no frequency band is provided in the ripple limit
table by default. The Edit Ripple Limit menu is also displayed, which can be used for
creating or editing the frequency band. The following are functions corresponding to each
softkey.
Softkey
Delete
Add
Clear Limit Table
Export to CSV File
Import from CSV File
Return
Chapter 11
to activate the channel to which you want to apply the
to activate the trace to which you want to apply the ripple
Function
Deletes the frequency band with the selected cell in the ripple limit table.
Adds a frequency band ahead of the one for the selected cell in the ripple
limit table.
Clears all of the data within the ripple limit table.
Outputs the ripple limit table to a file in the csv format. For further
information, see "Saving/recalling ripple limit table" on page 387.
Calls the ripple limit table saved in the csv format. For further
information, see "Saving/recalling ripple limit table" on page 387.
Ends the Edit Ripple Limit menu to close the ripple limit table.
Limit Test
Ripple Test
385