Softkey Functions
Calibration Menu
Key Operation
(Continued)
Displays softkeys for executing ECal (Electronic Calibrations).
ECal
Displays softkeys for executing 1-port ECal
1-Port ECal
Executes a 1-port ECal on test port 1.
Port 1
Executes a 1-port ECal on test port 2.
Port 2
*1
Executes a 1-port ECal on test port 3.
Port 3
*2
Executes a 1-port ECal on test port 4.
Port 4
Returns to the softkey display screen one level higher.
Return
Options 213 and 214: Execute a 2-port ECal.
2-Port ECal
Options 313, 314, 413, and 414: Display softkeys for executing a 2-port ECal.
Executes a 2-port ECal on test ports 1 and 2.
*1
Port 1-2
*1
Executes a 2-port ECal on test ports 1 and 3.
Port 1-3
*2
Executes a 2-port ECal on test ports 1 and 4.
Port 1-4
Executes a 2-port ECal on test ports 2 and 3.
*1
Port 2-3
Executes a 2-port ECal on test ports 2 and 4.
*2
Port 2-4
Executes a 2-port ECal on test ports 3 and 4.
*2
Port 3-4
Returns to the softkey display screen one level higher.
*1
Return
Options 313 and 314: Execute a 3-port ECal.
3-Port ECal
Options 413 and 414: Display softkeys for executing a 3-port ECal.
Executes a 3-port ECal on test ports 1, 2, and 3.
*2
Port 1-2-3
Executes a 3-port ECal on test ports 1, 2, and 4.
*2
Port 1-2-4
*2
Executes a 3-port ECal on test ports 1, 3, and 4.
Port 1-3-4
*2
Executes a 3-port ECal on test ports 2, 3, and 4.
Port 2-3-4
Returns to the softkey display screen one level higher.
*2
Return
Executes a 4-port ECal.
*2
4-Port ECal
Displays softkeys for executing a THRU ECal.
Thru ECal
Executes a THRU ECal for test port 1→2.
2-1 (S21)
Executes a THRU ECal for test port 1→3.
*1
3-1 (S31)
Executes a THRU ECal for test port 1→4.
*2
4-1 (S41)
Executes a THRU ECal for test port 2→1.
1-2 (S12)
*1
Executes a THRU ECal for test port 2→3.
3-2 (S32)
*2
Executes a THRU ECal for test port 2→4.
4-2 (S42)
Executes a THRU ECal for test port 3→1.
*1
1-3 (S13)
Executes a THRU ECal for test port 3→2.
*1
2-3 (S23)
Executes a THRU ECal for test port 3→4.
*2
4-3 (S43)
Executes a THRU ECal for test port 4→1.
*2
1-4 (S14)
*2
Executes a THRU ECal for test port 4→2.
2-4 (S24)
*2
Executes a THRU ECal for test port 4→3.
3-4 (S34)
Returns to the softkey display screen one level higher.
Return
674
Function
SCPI Command
:CALC{1-16}:SEL:FORM GDEL
:SENS{1-16}:CORR:COLL:ECAL:SOLT1 1
:SENS{1-16}:CORR:COLL:ECAL:SOLT1 2
:SENS{1-16}:CORR:COLL:ECAL:SOLT1 3
:SENS{1-16}:CORR:COLL:ECAL:SOLT1 4
:SENS{1-16}:CORR:COLL:ECAL:SOLT2 1,2
:SENS{1-16}:CORR:COLL:ECAL:SOLT2 1,3
:SENS{1-16}:CORR:COLL:ECAL:SOLT2 1,4
:SENS{1-16}:CORR:COLL:ECAL:SOLT2 2,3
:SENS{1-16}:CORR:COLL:ECAL:SOLT2 2,4
:SENS{1-16}:CORR:COLL:ECAL:SOLT2 3,4
:SENS{1-16}:CORR:COLL:ECAL:SOLT3 1,2,3
:SENS{1-16}:CORR:COLL:ECAL:SOLT3 1,2,4
:SENS{1-16}:CORR:COLL:ECAL:SOLT3 1,3,4
:SENS{1-16}:CORR:COLL:ECAL:SOLT3 2,3,4
:SENS{1-16}:CORR:COLL:ECAL:SOLT4
1,2,3,4
:SENS{1-16}:CORR:COLL:ECAL:THRU 2,1
:SENS{1-16}:CORR:COLL:ECAL:THRU 3,1
:SENS{1-16}:CORR:COLL:ECAL:THRU 4,1
:SENS{1-16}:CORR:COLL:ECAL:THRU 1,2
:SENS{1-16}:CORR:COLL:ECAL:THRU 3,2
:SENS{1-16}:CORR:COLL:ECAL:THRU 4,2
:SENS{1-16}:CORR:COLL:ECAL:THRU 1,3
:SENS{1-16}:CORR:COLL:ECAL:THRU 2,3
:SENS{1-16}:CORR:COLL:ECAL:THRU 4,3
:SENS{1-16}:CORR:COLL:ECAL:THRU 1,4
:SENS{1-16}:CORR:COLL:ECAL:THRU 2,4
:SENS{1-16}:CORR:COLL:ECAL:THRU 3,4