Key Operation
Displays softkeys for setting the E5091A control.
Multiport Test Set
Setup
Displays the model selected for test set 1 (ID=1)
Test Set 1
Displays softkeys for selecting a test port of the E5091A to which you want to connect port 3.
Port 3
Selects test port R1+.
R1+
Selects test port R2+.
R2+
Selects test port R3+.
R3+
*1
Selects test port R4+.
R4+
Returns to the softkey display screen one level higher.
Cancel
Displays softkeys for selecting a test port of the E5091A to which you want to connect port 4.
Port 4
Selects test port R1-.
R1-
Selects test port R2-.
R2-
Selects test port R3-.
R3-
Selects test port R4-.
*1
R4-
Returns to the softkey display screen one level higher.
Cancel
Displays softkeys for selecting a test port of the E5091A to which you want to connect port 5.
*1
Port 5
Selects test port X1.
X1
Selects test port X2.
X2
Returns to the softkey display screen one level higher.
Cancel
Displays softkeys for selecting a test port of the E5091A to which you want to connect port 6.
*1
Port 6
Selects test port Y1.
Y1
Selects test port Y1.
Y2
Returns to the softkey display screen one level higher.
Cancel
*1
Displays softkeys for selecting a test port of the E5091A to which you want to connect test port 7.
Port 7
Selects test port Z1.
Z1
Selects test port Z2.
Z2
Returns to the softkey display screen one level higher.
Cancel
Displays softkeys for setting HIGH/LOW of control lines.
Control Lines
Sets HIGH/LOW of line 1.
Line 1
Sets HIGH/LOW of line 2.
Line 2
Sets HIGH/LOW of line 3.
Line 3
Sets HIGH/LOW of line 4.
Line 4
Sets HIGH/LOW of line 5.
Line 5
Sets HIGH/LOW of line 6.
Line 6
Sets HIGH/LOW of line 7.
Line 7
Sets HIGH/LOW of line 8.
Line 8
Returns to the softkey display screen one level higher.
Return
Returns to the softkey display screen one level higher.
Return
Displays the model selected for test set 2.
Test Set 2
Returns to the softkey display screen one level higher.
Return
Appendix D
Function
Softkey Functions
System Menu
SCPI Command
:SENS{1-16}:MULT1:PORT3 R1
:SENS{1-16}:MULT1:PORT3 R2
Selects test port R2+.
Selects test port R2+.
:SENS{1-16}:MULT1:PORT4 R1
:SENS{1-16}:MULT1:PORT4 R2
:SENS{1-16}:MULT1:PORT4 R3
:SENS{1-16}:MULT1:PORT4 R4
:SENS{1-16}:MULT1:PORT5 X1
:SENS{1-16}:MULT1:PORT5 X2
:SENS{1-16}:MULT1:PORT6 Y1
:SENS{1-16}:MULT1:PORT6 Y2
:SENS{1-16}:MULT1:PORT7 Z1
:SENS{1-16}:MULT1:PORT7 Z2
:SENS{1-16}:MULT1:OUTP
:SENS{1-16}:MULT1:OUTP
:SENS{1-16}:MULT1:OUTP
:SENS{1-16}:MULT1:OUTP
:SENS{1-16}:MULT1:OUTP
:SENS{1-16}:MULT1:OUTP
:SENS{1-16}:MULT1:OUTP
:SENS{1-16}:MULT1:OUTP