Edge-Core ECS4660-28F Management Manual page 1210

Layer 3
Hide thumbs Also See for ECS4660-28F:
Table of Contents

Advertisement

| Interface Commands
C
31
HAPTER
Transceiver Threshold Configuration
transceiver-
threshold voltage
Low Warning: -21.00 dBm
Low Alarm: -21.50 dBm
C
M
OMMAND
ODE
Interface Configuration (Ethernet)
C
U
OMMAND
SAGE
The threshold value is the power ratio in decibels (dB) of the measured
power referenced to one milliwatt (mW).
Refer to the Command Usage section under the
current
command for more information on configuring transceiver
thresholds.
Trap messages enabled by the
are sent to any management station configured by the
host
command.
E
XAMPLE
The following example sets alarm thresholds for the signal power
transmitted at port 1.
Console(config)interface ethernet 1/1
Console(config-if)#transceiver-threshold tx-power low-alarm 8
Console(config-if)#transceiver-threshold tx-power high-alarm -3
Console#
This command sets thresholds for the transceiver voltage which can be
used to trigger an alarm or warning message.
S
YNTAX
transceiver-threshold voltage {high-alarm | high-warning | low-
alarm | low-warning} threshold-value
high-alarm – Sets the high voltage threshold for an alarm
message.
high-warning – Sets the high voltage threshold for a warning
message.
low-alarm – Sets the low voltage threshold for an alarm message.
low-warning – Sets the low voltage threshold for a warning
message.
threshold-value – The threshold of the transceiver voltage.
(Range: 100-25500 in units of 0.01 Volt)
D
S
EFAULT
ETTING
High Alarm: 3.50 Volts
HIgh Warning: 3.45 Volts
Low Warning: 3.15 Volts
Low Alarm: 3.10 Volts