Edge-Core ECS4660-28F Management Manual page 1209

Layer 3
Hide thumbs Also See for ECS4660-28F:
Table of Contents

Advertisement

transceiver-
threshold tx-power
D
S
EFAULT
ETTING
°
High Alarm: 75.00
C
°
HIgh Warning: 70.00
C
°
Low Alarm: -123.00
C
°
Low Warning: 0.00
C
C
M
OMMAND
ODE
Interface Configuration (Ethernet)
C
U
OMMAND
SAGE
Refer to the Command Usage section under the
current
command for more information on configuring transceiver
thresholds.
Trap messages enabled by the
are sent to any management station configured by the
host
command.
E
XAMPLE
The following example sets alarm thresholds for the transceiver
temperature at port 1.
Console(config)interface ethernet 1/1
Console(config-if)#transceiver-threshold temperature low-alarm 97
Console(config-if)#transceiver-threshold temperature high-alarm -83
Console#
This command sets thresholds for the transceiver power level of the
transmitted signal which can be used to trigger an alarm or warning
message.
S
YNTAX
transceiver-threshold tx-power {high-alarm | high-warning |
low-alarm | low-warning} threshold-value
high-alarm – Sets the high power threshold for an alarm message.
high-warning – Sets the high power threshold for a warning
message.
low-alarm – Sets the low power threshold for an alarm message.
low-warning – Sets the low power threshold for a warning
message.
threshold-value – The power threshold of the transmitted signal.
(Range: -9999 - 9999 in units of 0.01 dBm)
D
S
EFAULT
ETTING
High Alarm: -9.00 dBm
HIgh Warning: -9.50 dBm
– 1209 –
| Interface Commands
C
31
HAPTER
Transceiver Threshold Configuration
transceiver-threshold
transceiver-threshold-monitor
command
snmp-server

Advertisement

Table of Contents
loading

Table of Contents