Edge-Core ECS4660-28F Management Manual page 1539

Layer 3
Hide thumbs Also See for ECS4660-28F:
Table of Contents

Advertisement

lldp
lldp
holdtime-multiplier
This command enables LLDP globally on the switch. Use the no form to
disable LLDP.
S
YNTAX
[no] lldp
D
S
EFAULT
ETTING
Enabled
C
M
OMMAND
ODE
Global Configuration
E
XAMPLE
Console(config)#lldp
Console(config)#
This command configures the time-to-live (TTL) value sent in LLDP
advertisements. Use the no form to restore the default setting.
S
YNTAX
lldp holdtime-multiplier value
no lldp holdtime-multiplier
value - Calculates the TTL in seconds based on the following rule:
minimum of ((Transmission Interval * Holdtime Multiplier), or 65536)
(Range: 2 - 10)
D
S
EFAULT
ETTING
Holdtime multiplier: 4
TTL: 4*30 = 120 seconds
C
M
OMMAND
ODE
Global Configuration
C
U
OMMAND
SAGE
The time-to-live tells the receiving LLDP agent how long to retain all
information pertaining to the sending LLDP agent if it does not transmit
updates in a timely manner.
E
XAMPLE
Console(config)#lldp holdtime-multiplier 10
Console(config)#
– 1539 –
| LLDP Commands
C
44
HAPTER

Advertisement

Table of Contents
loading

Table of Contents