Edge-Core ECS4660-28F Management Manual page 1570

Layer 3
Hide thumbs Also See for ECS4660-28F:
Table of Contents

Advertisement

| CFM Commands
C
45
HAPTER
Defining CFM Structures
ma index name
This command creates a maintenance association (MA) within the current
maintenance domain, maps it to a customer service instance (S-VLAN),
and sets the manner in which MIPs are created for this service instance.
Use the no form with the vlan keyword to remove the S-VLAN from the
specified MA. Or use the no form with only the index keyword to remove
the MA from the current domain.
S
YNTAX
ma index index name ma-name [vlan vlan-id [mip-creation type]]
no ma index index [vlan vlan-id]
index – MA identifier. (Range: 1-2147483647)
ma-name – MA name. (Range: 1-44 alphanumeric characters)
vlan-id - Service VLAN ID. (Range: 1-4094)
type – Specifies the CFM protocol's creation method for
maintenance intermediate points (MIPs) in this MA:
default – MIPs can be created for this MA on any bridge port
through which the MA's VID can pass.
explicit – MIPs can be created this MA only on bridge ports
through which the MA's VID can pass, and only if a maintenance
end point (MEP) is created at some lower MA Level.
none – No MIP can be created for this MA.
D
S
EFAULT
ETTING
10 seconds
C
M
OMMAND
ODE
CFM Domain Configuration
C
U
OMMAND
SAGE
The maintenance domain used to enter CFM domain configuration
mode, the MA name and VLAN identifier specified by this command,
and the DSAPs configured with the
create a unique service instance for each customer.
If only the MA index and name are entered for this command, the MA
will be recorded in the domain database, but will not function. No MEPs
can be created until the MA is associated with a service VLAN.
Note that multiple domains at the same maintenance level (see the
ethernet cfm domain
Also, each MA name must be unique within the CFM-managed network.
Before removing an MA, first remove all the MEPs configured for it (see
the
mep crosscheck mpid
If the MIP creation method is not defined by this command, the
creation method defined by the
applied to this MA. For a detailed description of the MIP types, refer to
the Command Usage section under the
– 1570 –
mep crosscheck mpid
command) cannot have an MA on the same VLAN.
command).
ethernet cfm domain
ethernet cfm domain
command
command is
command.

Advertisement

Table of Contents
loading

Table of Contents