| Interface Commands
C
31
HAPTER
Transceiver Threshold Configuration
transceiver-
threshold
temperature
D
S
EFAULT
ETTING
High Alarm: -3.00 dBm
HIgh Warning: -3.50 dBm
Low Warning: -21.00 dBm
Low Alarm: -21.50 dBm
C
M
OMMAND
ODE
Interface Configuration (Ethernet)
C
U
OMMAND
SAGE
The threshold value is the power ratio in decibels (dB) of the measured
◆
power referenced to one milliwatt (mW).
Refer to the Command Usage section under the
◆
current
command for more information on configuring transceiver
thresholds.
Trap messages enabled by the
◆
are sent to any management station configured by the
host
command.
E
XAMPLE
The following example sets alarm thresholds for the signal power received
at port 1.
Console(config)interface ethernet 1/1
Console(config-if)#transceiver-threshold rx-power low-alarm -21
Console(config-if)#transceiver-threshold rx-power high-alarm -3
Console#
This command sets thresholds for the transceiver temperature which can
be used to trigger an alarm or warning message.
S
YNTAX
transceiver-threshold temperature {high-alarm | high-warning
| low-alarm | low-warning} threshold-value
high-alarm – Sets the high temperature threshold for an alarm
message.
high-warning – Sets the high temperature threshold for a warning
message.
low-alarm – Sets the low temperature threshold for an alarm
message.
low-warning – Sets the low temperature threshold for a warning
message.
threshold-value – The threshold of the transceiver temperature.
(Range: -20000 - 20000 in units of 0.01 Celsius)
– 1208 –
transceiver-threshold
transceiver-threshold-monitor
command
snmp-server