Table 149: Show Udld - Display Description - Edge-Core ECS4660-28F Management Manual

Layer 3
Hide thumbs Also See for ECS4660-28F:
Table of Contents

Advertisement

| UniDirectional Link Detection Commands
C
36
HAPTER
show udld
This command shows UDLD configuration settings and operational status
for the switch or for a specified interface.
S
YNTAX
show udld [interface interface]
interface
ethernet unit/port
unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-28)
C
M
OMMAND
ODE
Privileged Exec
E
XAMPLE
Console#show udld
Message Interval : 15
Interface UDLD
Mode
--------- -------- ---------- ------------------------------------- --------
Eth 1/ 1
Enabled
Aggressive Advertisement
Eth 1/ 2
Disabled Normal
Eth 1/ 3
Disabled Normal
Eth 1/ 4
Disabled Normal
Eth 1/ 5
Disabled Normal
. .
.
Console#show udld interface ethernet 1/1
Interface UDLD
Mode
--------- -------- ---------- ------------------------------------- --------
Eth 1/ 1
Enabled
Aggressive Advertisement
Console#

Table 149: show udld - display description

Field
Description
Message Interval
The interval between UDLD probe messages for ports in advertisement
phase
UDLD
Shows if UDLD is enabled or disabled on a port
Mode
Shows if UDLD is functioning in Normal or Aggressive mode
Oper State
Shows the UDLD operational state (Disabled, Link down, Link up,
Advertisement, Detection, Disabled port, Advertisement - Single
neighbor, Advertisement - Multiple neighbors)
– 1268 –
Oper State
Port State
Bidirectional
Disabled
Unknown
Disabled
Unknown
Disabled
Unknown
Disabled
Unknown
Oper State
Port State
Bidirectional
Msg Invl
Timeout
15 s
5 s
7 s
5 s
7 s
5 s
7 s
5 s
7 s
5 s
Msg Invl
Timeout
15 s
5 s

Advertisement

Table of Contents
loading