Danfoss VLT AutomationDrive FC 301 Programming Manual page 69

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Parameter Descriptions
3-02 Minimum Reference
Range:
3-03 Maximum Reference
Range:
1500.000
[par. 3-02 -
ReferenceFeed-
999999.999
backUnit
ReferenceFeed-
*
backUnit]
3-04 Reference Function
Option:
Function:
[0] Sum
Sums both external and preset reference
sources.
[1] External/
Use either the preset or the external reference
Preset
source.
Shift between external and preset via a
command or a digital input.
3-05 On Reference Window
Range:
Function:
NOTICE
Size
[0 - 999999.999
related
ReferenceFeed-
*
This parameter is only available
backUnit]
with software version 48.XX.
Enter the tolerance window for on
reference or on target status.
Depending on the option selected
in parameter 1-00 Configuration
Mode, this parameter defines the
following:
MG33MO02
Programming Guide
Function:
deviation when performing the
position offset defined in
parameter 3-26 Master Offset.
Function:
Enter the maximum reference.
The maximum reference is the
highest value obtainable by
summing all references.
The maximum reference unit
matches:
The configuration
selected in
parameter 1-00 Configu-
ration Mode: For [1]
Speed closed loop, RPM;
for [2] Torque, Nm.
The unit selected in
parameter 3-00 Reference
Range.
If [9] Positioning is selected in
parameter 1-00 Configuration
Mode, this parameter defines the
default speed for positioning.
Danfoss A/S © 01/2018 All rights reserved.
3-05 On Reference Window
Range:
Function:
3-06 Minimum Position
Range:
-100000
[ -2147483648
CustomRea-
- 2147483647
doutUnit2
CustomRea-
*
doutUnit2]
3-07 Maximum Position
Range:
NOTICE
100000
CustomRea-
[ -2147483647
This parameter is only
doutUnit2
- 2147483647
*
available with software
CustomRea-
version 48.XX.
doutUnit2]
Enter the maximum position. This
parameter defines the position
range in linear and axis modes
(parameter 17-76 Position Axis
Mode).
Position range limits:
The position limit function uses
this parameter
Speed mode: Speed
window for on reference
status.
Torque mode: Torque
window for on reference
status.
Position mode: Speed
window for on target
status. See also
parameter 3-08 On Target
Window.
Function:
NOTICE
This parameter is only
available with software
version 48.XX.
Enter the minimum position.
This parameter defines the
position range in linear axis
mode (parameter 17-76 Position
Axis Mode) and in the position
limit function
(parameter 4-73 Position Limit
Function).
Function:
Linear:
Parameter 3-06 Minimum
Position to
parameter 3-07 Maximum
Position.
Rotary: 0–
parameter 3-07 Maximum
Position.
67
3
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt automationdrive fc 302

Table of Contents