Parameter Lists
3-84
Quick Stop S-ramp Ratio at Decel. End
3-89
Ramp Lowpass Filter Time
3-9* Digital Pot.Meter
3-90
Step Size
3-91
Ramp Time
3-92
Power Restore
3-93
Maximum Limit
3-94
Minimum Limit
3-95
Ramp Delay
5.2.5 4-** Limits / Warnings
Para
Parameter description
mete
r
num
ber
4-1* Motor Limits
4-10
Motor Speed Direction
4-11
Motor Speed Low Limit [RPM]
4-12
Motor Speed Low Limit [Hz]
4-13
Motor Speed High Limit [RPM]
4-14
Motor Speed High Limit [Hz]
4-16
Torque Limit Motor Mode
4-17
Torque Limit Generator Mode
4-18
Current Limit
4-19
Max Output Frequency
4-2* Limit Factors
4-20
Torque Limit Factor Source
4-21
Speed Limit Factor Source
4-23
Brake Check Limit Factor Source
4-24
Brake Check Limit Factor
4-25
Power Limit Motor Factor Source
4-26
Power Limit Gener. Factor Source
4-3* Motor Speed Mon.
4-30
Motor Feedback Loss Function
4-31
Motor Feedback Speed Error
4-32
Motor Feedback Loss Timeout
4-34
Tracking Error Function
4-35
Tracking Error
4-36
Tracking Error Timeout
4-37
Tracking Error Ramping
4-38
Tracking Error Ramping Timeout
4-39
Tracking Error After Ramping Timeout
4-4* Speed Monitor
4-43
Motor Speed Monitor Function
4-44
Motor Speed Monitor Max
4-45
Motor Speed Monitor Timeout
4-5* Adj. Warnings
4-50
Warning Current Low
4-51
Warning Current High
4-52
Warning Speed Low
4-53
Warning Speed High
4-54
Warning Reference Low
MG33MO02
Programming Guide
50 %
All set-ups
1 ms
All set-ups
0.10 %
All set-ups
1 s
All set-ups
[0] Off
All set-ups
100 %
All set-ups
-100 %
All set-ups
ExpressionLimit
All set-ups
Default value
4 set-up
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
100 %
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] No function
All set-ups
[0] No function
All set-ups
[0] DC-link voltage
All set-ups
98 %
All set-ups
[0] No function
All set-ups
[0] No function
All set-ups
ExpressionLimit
All set-ups
300 RPM
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
10 RPM
All set-ups
1 s
All set-ups
100 RPM
All set-ups
1 s
All set-ups
5 s
All set-ups
ExpressionLimit
All set-ups
300 RPM
All set-ups
0.1 s
All set-ups
0 A
All set-ups
ImaxVLT (P1637)
All set-ups
0 RPM
All set-ups
ExpressionLimit
All set-ups
-999999.999 N/A
All set-ups
Danfoss A/S © 01/2018 All rights reserved.
TRUE
0
TRUE
-4
TRUE
-2
TRUE
-2
TRUE
-
TRUE
0
TRUE
0
TRUE
-3
FC 302 only
Change
Conversio
during
n index
operation
FALSE
-
TRUE
67
TRUE
-1
TRUE
67
TRUE
-1
TRUE
-1
TRUE
-1
TRUE
-1
FALSE
-1
TRUE
-
TRUE
-
TRUE
-
TRUE
0
x
TRUE
-
x
TRUE
-
TRUE
-
TRUE
67
TRUE
-2
TRUE
-
TRUE
67
TRUE
-2
TRUE
67
TRUE
-2
TRUE
-2
TRUE
-
TRUE
67
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
67
TRUE
67
TRUE
-3
Uint8
Uint16
Uint16
Uint32
Uint8
Int16
Int16
TimD
5
5
Type
Uint8
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint32
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint16
Uint8
Uint16
Uint16
Uint16
Uint16
Uint16
Uint8
Uint16
Uint16
Uint32
Uint32
Uint16
Uint16
Int32
233