Parameter Lists
5.2.11 10-** CAN Fieldbus
Para
Parameter description
mete
r
num
ber
10-0* Common Settings
10-00 CAN Protocol
10-01 Baud Rate Select
10-02 MAC ID
5
5
10-05 Readout Transmit Error Counter
10-06 Readout Receive Error Counter
10-07 Readout Bus Off Counter
10-1* DeviceNet
10-10 Process Data Type Selection
10-11 Process Data Config Write
10-12 Process Data Config Read
10-13 Warning Parameter
10-14 Net Reference
10-15 Net Control
10-2* COS Filters
10-20 COS Filter 1
10-21 COS Filter 2
10-22 COS Filter 3
10-23 COS Filter 4
10-3* Parameter Access
10-30 Array Index
10-31 Store Data Values
10-32 Devicenet Revision
10-33 Store Always
10-34 DeviceNet Product Code
10-39 Devicenet F Parameters
10-5* CANopen
10-50 Process Data Config Write.
10-51 Process Data Config Read.
5.2.12 12-** Ethernet
Para
Parameter description
mete
r
num
ber
12-0* IP Settings
12-00 IP Address Assignment
12-01 IP Address
12-02 Subnet Mask
12-03 Default Gateway
12-04 DHCP Server
240
®
VLT
AutomationDrive FC 301/302
Default value
ExpressionLimit
ExpressionLimit
ExpressionLimit
0 N/A
0 N/A
0 N/A
ExpressionLimit
ExpressionLimit
ExpressionLimit
0 N/A
[0] Off
[0] Off
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
[0] Off
ExpressionLimit
[0] Off
ExpressionLimit
0 N/A
ExpressionLimit
ExpressionLimit
Default value
ExpressionLimit
0 N/A
0 N/A
0 N/A
0 N/A
Danfoss A/S © 01/2018 All rights reserved.
4 set-up
FC 302 only
Change
during
operation
2 set-ups
FALSE
2 set-ups
TRUE
2 set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
2 set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
4 set-up
FC 302 only
Change
during
operation
2 set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
2 set-ups
TRUE
Conversio
Type
n index
-
Uint8
-
Uint8
0
Uint8
0
Uint8
0
Uint8
0
Uint8
-
Uint8
-
Uint16
-
Uint16
0
Uint16
-
Uint8
-
Uint8
0
Uint16
0
Uint16
0
Uint16
0
Uint16
0
Uint8
-
Uint8
0
Uint16
-
Uint8
0
Uint16
0
Uint32
-
Uint16
-
Uint16
Conversio
Type
n index
-
Uint8
OctStr[
0
4]
OctStr[
0
4]
OctStr[
0
4]
OctStr[
0
4]
MG33MO02