Danfoss VLT AutomationDrive FC 301 Programming Manual page 240

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Parameter Lists
7-57
Process PID Fb. Filter Time
5.2.9 8-** Comm. and Options
Para
Parameter description
mete
r
num
ber
8-0* General Settings
8-01
Control Site
5
5
8-02
Control Word Source
8-03
Control Word Timeout Time
8-04
Control Word Timeout Function
8-05
End-of-Timeout Function
8-06
Reset Control Word Timeout
8-07
Diagnosis Trigger
8-08
Readout Filtering
8-1* Ctrl. Word Settings
8-10
Control Word Profile
8-13
Configurable Status Word STW
8-14
Configurable Control Word CTW
8-17
Configurable Alarm and Warningword
8-19
Product Code
8-3* FC Port Settings
8-30
Protocol
8-31
Address
8-32
FC Port Baud Rate
8-33
Parity / Stop Bits
8-34
Estimated cycle time
8-35
Minimum Response Delay
8-36
Max Response Delay
8-37
Max Inter-Char Delay
8-4* FC MC protocol set
8-40
Telegram Selection
8-41
Parameters for Signals
8-42
PCD Write Configuration
8-43
PCD Read Configuration
8-45
BTM Transaction Command
8-46
BTM Transaction Status
8-47
BTM Timeout
8-48
BTM Maximum Errors
8-49
BTM Error Log
8-5* Digital/Bus
8-50
Coasting Select
8-51
Quick Stop Select
8-52
DC Brake Select
8-53
Start Select
8-54
Reversing Select
8-55
Set-up Select
8-56
Preset Reference Select
8-57
Profidrive OFF2 Select
8-58
Profidrive OFF3 Select
8-8* FC Port Diagnostics
238
®
VLT
AutomationDrive FC 301/302
0.001 s
Default value
[0] Digital and ctrl.word
ExpressionLimit
1 s
ExpressionLimit
[1] Resume set-up
[0] Do not reset
[0] Disable
ExpressionLimit
[0] FC profile
ExpressionLimit
[1] Profile default
[0] Off
ExpressionLimit
[0] FC
1 N/A
ExpressionLimit
[0] Even Parity, 1 Stop Bit
0 ms
10 ms
ExpressionLimit
ExpressionLimit
[1] Standard telegram 1
0
ExpressionLimit
ExpressionLimit
[0] Off
[0] Off
60 s
21 N/A
0.255 N/A
[3] Logic OR
[3] Logic OR
ExpressionLimit
[3] Logic OR
ExpressionLimit
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
Danfoss A/S © 01/2018 All rights reserved.
All set-ups
TRUE
4 set-up
FC 302 only
Change
during
operation
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
2 set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
2 set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
2 set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
2 set-ups
TRUE
All set-ups
FALSE
2 set-ups
TRUE
2 set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
1 set-up
FALSE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
-3
Uint16
Conversio
Type
n index
-
Uint8
-
Uint8
-1
Uint32
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint16
0
Uint32
-
Uint8
0
Uint8
-
Uint8
-
Uint8
-3
Uint32
-3
Uint16
-3
Uint16
-5
Uint16
-
Uint8
-
Uint16
0
Uint16
0
Uint16
-
Uint8
-
Uint8
0
Uint16
0
Uint8
-3
Uint32
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
MG33MO02