Parameter Lists
6-74
Terminal X45/1 Output Timeout Preset
6-8* Analog Output 4
6-80
Terminal X45/3 Output
6-81
Terminal X45/3 Min. Scale
6-82
Terminal X45/3 Max. Scale
6-83
Terminal X45/3 Bus Control
6-84
Terminal X45/3 Output Timeout Preset
5.3.8 7-** Controllers
Par-
Parameter description
ameter #
7-0* Speed PID Ctrl.
7-00
Speed PID Feedback Source
7-01
Speed PID Droop
7-02
Speed PID Proportional Gain
7-03
Speed PID Integral Time
7-04
Speed PID Differentiation Time
7-05
Speed PID Diff. Gain Limit
7-06
Speed PID Lowpass Filter Time
7-07
Speed PID Feedback Gear Ratio
7-08
Speed PID Accel. Feed Forward Factor
7-09
Speed PID Error Correction w/ Ramp
7-1* Torque PI Ctrl.
7-10
Torque PI Feedback Source
7-12
Torque PI Proportional Gain
7-13
Torque PI Integration Time
7-16
Torque PI Lowpass Filter Time
7-18
Torque PI Feed Forward Factor
7-19
Current Controller Rise Time
7-2* Process Ctrl. Feedb
7-20
Process CL Feedback 1 Resource
7-22
Process CL Feedback 2 Resource
7-3* Process PID Ctrl.
7-30
Process PID Normal/ Inverse Control
7-31
Process PID Anti Windup
7-32
Process PID Start Speed
7-33
Process PID Proportional Gain
7-34
Process PID Integral Time
7-35
Process PID Differentiation Time
7-36
Process PID Diff. Gain Limit
7-38
Process PID Feed Forward Factor
7-39
On Reference Bandwidth
7-9* Position PI Ctrl.
7-90
Position PI Feedback Source
7-91
Position PI Droop
7-92
Position PI Proportional Gain
7-93
Position PI Integral Time
7-94
Position PI Feedback Scale Numerator
Position PI Feebback Scale
7-95
Denominator
Position PI Maximum Speed Above
7-97
Master
MG33MO02
Programming Guide
0 %
ExpressionLimit
0 %
100 %
0 %
0 %
Default value
ExpressionLimit
0 RPM
0.015 N/A
ExpressionLimit
ExpressionLimit
5 N/A
ExpressionLimit
1 N/A
0 %
300 RPM
[0] Controller Off
100 %
0.020 s
5 ms
0 %
ExpressionLimit
[0] No function
[0] No function
[0] Normal
[1] On
0 RPM
0.01 N/A
10000 s
0 s
5 N/A
0 %
5 %
[0] Motor feedb. P1-02
0.0 °
0.0150 N/A
20000.0 ms
1 N/A
1 N/A
100 RPM
Danfoss A/S © 01/2018 All rights reserved.
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
4 set-up
FC 302
Change
only
during
operation
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
-2
Uint16
-
Uint8
-2
Int16
-2
Int16
-2
N2
-2
Uint16
Conversi
Type
5
5
on index
-
Uint8
67
Uint16
-3
Uint16
-4
Uint32
-4
Uint16
-1
Uint16
-4
Uint16
-4
Uint32
0
Uint16
67
Uint32
-
Uint8
0
Uint16
-3
Uint16
-4
Uint16
0
Uint16
0
Uint16
-
Uint8
-
Uint8
-
Uint8
-
Uint8
67
Uint16
-2
Uint16
-2
Uint32
-2
Uint16
-1
Uint16
0
Uint16
0
Uint8
-
Uint8
-1
Uint16
-4
Uint32
-4
Uint32
0
Int32
0
Int32
67
Uint16
265