Parameter Descriptions
3.2.6 1-2* Motor Data
This parameter group contains input data from the
nameplate on the connected motor.
3
3
NOTICE
Changing the value of these parameters affects the
setting of other parameters.
NOTICE
The following parameters have no effect when
parameter 1-10 Motor Construction is set to [1] PM, non-
salient SPM, [2] PM, salient IPM, [5] Sync. Reluctance:
Parameter 1-20 Motor Power [kW].
Parameter 1-21 Motor Power [HP].
Parameter 1-22 Motor Voltage.
Parameter 1-23 Motor Frequency.
1-20 Motor Power [kW]
Range:
4.00
[0.09 -
kW
3000.00
*
kW]
1-21 Motor Power [HP]
Range:
4.00
[0.09 -
hp
3000.00
*
hp]
1-22 Motor Voltage
Range:
500. V
[10. - 1000.
*
V]
40
®
VLT
Function:
NOTICE
This parameter cannot be adjusted
while the motor is running.
Enter the nominal motor power in kW
according to the motor nameplate data. The
default value corresponds to the nominal
rated output of the frequency converter.
This parameter is visible in the LCP if
parameter 0-03 Regional Settings is set to [0]
International.
Function:
Enter the nominal motor power in hp
according to the motor nameplate data. The
default value corresponds to the nominal
rated output of the unit. This parameter is
visible in the LCP if parameter 0-03 Regional
Settings is [1] US.
Function:
Enter the nominal motor voltage
according to the motor nameplate data.
The default value corresponds to the
nominal rated output of the unit.
Danfoss A/S © 01/2018 All rights reserved.
AutomationDrive FC 301/302
1-23 Motor Frequency
Range:
50.
[20 -
Hz
1000
*
Hz]
1-24 Motor Current
Range:
7.20 A
[0.10 -
*
10000.00 A]
1-25 Motor Nominal Speed
Range:
1420.
[10 - 60000
RPM
RPM]
*
1-26 Motor Cont. Rated Torque
Range:
0 Nm
[0.1 -
*
10000.0
Nm]
1-29 Automatic Motor Adaptation (AMA)
Option:
Function:
NOTICE
From software version 6.72 onwards, the
output frequency of the frequency
converter is limited to 590 Hz.
Select the motor frequency value from the motor
nameplate data. If a value other than 50 Hz or 60
Hz is selected, adapt the load-independent
settings in parameter 1-50 Motor Magnetisation at
Zero Speed to parameter 1-53 Model Shift
Frequency. For 87 Hz operation with 230/400 V
motors, set the nameplate data for 230 V/50 Hz.
To run at 87 Hz, adapt parameter 4-13 Motor
Speed High Limit [RPM] and
parameter 3-03 Maximum Reference.
Function:
Enter the nominal motor current value
from the motor nameplate data. The
data is used for calculating torque,
motor overload protection, and so on.
Function:
Enter the nominal motor speed value
from the motor nameplate data. The
data is used for calculating motor
compensations. n
= n
m,n
Function:
Enter the value from the motor nameplate
data. The default value corresponds to the
nominal rated output. This parameter is
available when parameter 1-10 Motor
Construction is set to [1] PM, non-salient SPM,
that is the parameter is valid for PM and
non-salient SPM motors only.
Function:
NOTICE
This parameter cannot be adjusted while
the motor is running.
The AMA function optimizes dynamic motor
performance by automatically optimizing the
advanced motor parameters
(parameter 1-30 Stator Resistance (Rs) to
parameter 1-35 Main Reactance (Xh)) at motor
standstill.
- n
.
s
slip
MG33MO02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt automationdrive fc 302

Table of Contents