Parameter Lists
18-37 Temp. Input X48/4
18-38 Temp. Input X48/7
18-39 Temp. Input X48/10
18-4* PGIO Data Readouts
18-43 Analog Out X49/7
18-44 Analog Out X49/9
18-45 Analog Out X49/11
18-5* Active Alarms/Warnings
18-55 Active Alarm Numbers
18-56 Active Warning Numbers
18-6* Inputs & Outputs 2
18-60 Digital Input 2
18-7* Rectifier Status
18-70 Mains Voltage
18-71 Mains Frequency
18-72 Mains Imbalance
18-75 Rectifier DC Volt.
18-9* PID Readouts
18-90 Process PID Error
18-91 Process PID Output
18-92 Process PID Clamped Output
18-93 Process PID Gain Scaled Output
5.2.19 30-** Special Features
Para
Parameter description
mete
r
num
ber
30-0* Wobbler
30-00 Wobble Mode
30-01 Wobble Delta Frequency [Hz]
30-02 Wobble Delta Frequency [%]
30-03 Wobble Delta Freq. Scaling Resource
30-04 Wobble Jump Frequency [Hz]
30-05 Wobble Jump Frequency [%]
30-06 Wobble Jump Time
30-07 Wobble Sequence Time
30-08 Wobble Up/ Down Time
30-09 Wobble Random Function
30-10 Wobble Ratio
30-11 Wobble Random Ratio Max.
30-12 Wobble Random Ratio Min.
30-19 Wobble Delta Freq. Scaled
30-2* Adv. Start Adjust
30-20 High Starting Torque Time [s]
30-21 High Starting Torque Current [%]
30-22 Locked Rotor Protection
30-23 Locked Rotor Detection Time [s]
30-24 Locked Rotor Detection Speed Error [%]
30-25 Light Load Delay [s]
30-26 Light Load Current [%]
30-27 Light Load Speed [%]
MG33MO02
Programming Guide
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 V
All set-ups
0 Hz
All set-ups
0 %
All set-ups
0 V
All set-ups
0 %
All set-ups
0 %
All set-ups
0 %
All set-ups
0 %
All set-ups
Default value
4 set-up
[0] Abs. Freq., Abs. Time
All set-ups
5 Hz
All set-ups
25 %
All set-ups
[0] No function
All set-ups
0 Hz
All set-ups
0 %
All set-ups
ExpressionLimit
All set-ups
10 s
All set-ups
5 s
All set-ups
[0] Off
All set-ups
1 N/A
All set-ups
10 N/A
All set-ups
0.1 N/A
All set-ups
0 Hz
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
25 %
All set-ups
0.000 s
All set-ups
0 %
All set-ups
0 %
All set-ups
Danfoss A/S © 01/2018 All rights reserved.
TRUE
0
TRUE
0
TRUE
0
FALSE
-3
FALSE
-3
FALSE
-3
TRUE
0
TRUE
0
FALSE
0
x
TRUE
0
x
TRUE
-1
x
TRUE
-1
x
TRUE
0
FALSE
-1
FALSE
-1
FALSE
-1
FALSE
-1
FC 302 only
Change
Conversio
during
n index
operation
FALSE
-
TRUE
-1
TRUE
0
TRUE
-
TRUE
-1
TRUE
0
TRUE
-3
TRUE
-1
TRUE
-1
TRUE
-
TRUE
-1
TRUE
-1
TRUE
-1
FALSE
-1
x
TRUE
-2
x
TRUE
-1
x
TRUE
-
x
TRUE
-2
x
TRUE
-1
x
TRUE
-3
x
TRUE
0
x
TRUE
0
Int16
Int16
Int16
Int16
Int16
Int16
Uint16
Uint16
5
5
Uint16
Uint16
Int16
Uint16
Uint16
Int16
Int16
Int16
Int16
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint16
Uint16
Uint8
Uint8
Uint8
Uint8
Uint16
Uint16
Uint32
Uint8
Uint8
Uint32
Uint32
Uint16
Uint16
249