Danfoss VLT AutomationDrive FC 301 Programming Manual page 184

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Parameter Descriptions
15-33 Alarm Log: Date and Time
Array [10]
Range:
Size related
*
3
3
3.15.9 15-4* Drive Identification
Parameters containing read-only information about the
hardware and software configuration of the frequency
converter.
15-40 FC Type
Range:
0 N/A
[0 - 0 N/A] View the frequency converter type. The
*
15-41 Power Section
Range:
0 N/A
[0 - 0 N/A] View the frequency converter type. The
*
15-42 Voltage
Range:
0 N/A
[0 - 0
*
N/A]
15-43 Software Version
Range:
0
[0 - 5 ] View the combined SW version (or package
*
15-44 Ordered Typecode String
Range:
0
[0 - 40 ] View the type code string used for reordering the
*
15-45 Actual Typecode String
Range:
0
[0 - 40 ]
*
15-46 Frequency Converter Ordering No
Range:
0
[0 - 8 ] View the 8-digit ordering number used for
*
182
Function:
[ 0 - 0 ] Array parameter; Date & Time 0–9: This
parameter shows at which time the
logged event occurred.
Function:
readout is identical to the FC 300 power
field of the type code definition, characters
1–6.
Function:
readout is identical to the FC 300 power
field of the type code definition, characters
7–10.
Function:
View the frequency converter type. The
readout is identical to the FC 300 power
field of the type code definition, characters
11–12.
Function:
version) consisting of power SW and control SW.
Function:
frequency converter in its original configuration.
Function:
View the actual type code string.
Function:
reordering the frequency converter in its original
configuration. To restore the ordering number after
Danfoss A/S © 01/2018 All rights reserved.
®
VLT
AutomationDrive FC 301/302
15-46 Frequency Converter Ordering No
Range:
15-47 Power Card Ordering No
Range:
0
[0 - 8 ]
*
15-48 LCP Id No
Range:
0
[0 - 20 ]
*
15-49 SW ID Control Card
Range:
0
[0 - 20 ]
*
15-50 SW ID Power Card
Range:
0
[0 - 20 ]
*
15-51 Frequency Converter Serial Number
Range:
0
[0 - 10 ]
*
15-53 Power Card Serial Number
Range:
0
[0 - 19 ]
*
15-54 Config File Name
Array [5]
Range:
Size related
15-58 Smart Setup Filename
Range:
Size related
15-59 Filename
Range:
Size related
Function:
the power card exchange, see
parameter 14-29 Service Code.
Function:
View the power card ordering number.
Function:
View the LCP ID number.
Function:
View the control card software version number.
Function:
View the power card software version number.
Function:
View the frequency converter serial number.
Function:
View the power card serial number.
Function:
[0 - 16] Shows the special configuration file
*
names.
Function:
[0 - 20 ]
Shows the SmartStart filename.
*
Function:
[0 - 16] Shows the currently used customer-
*
specific initial values (CSIV) filename.
MG33MO02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt automationdrive fc 302

Table of Contents