Parameter Lists
13-92 Alert Text
13-9* User Defined Readouts
13-97 Alert Alarm Word
13-98 Alert Warning Word
13-99 Alert Status Word
5.2.14 14-** Special Functions
Para
Parameter description
mete
r
num
ber
14-0* Inverter Switching
14-00 Switching Pattern
14-01 Switching Frequency
14-03 Overmodulation
14-04 Acoustic Noise Reduction
14-06 Dead Time Compensation
14-1* Mains Failure
14-10 Mains Failure
14-11 Mains Fault Voltage Level
14-12 Response to Mains Imbalance
14-14 Kin. Back-up Time-out
14-15 Kin. Back-up Trip Recovery Level
14-16 Kin. Back-up Gain
14-2* Trip Reset
14-20 Reset Mode
14-21 Automatic Restart Time
14-22 Operation Mode
14-23 Typecode Setting
14-24 Trip Delay at Current Limit
14-25 Trip Delay at Torque Limit
14-26 Trip Delay at Inverter Fault
14-28 Production Settings
14-29 Service Code
14-3* Current Limit Ctrl.
14-30 Current Lim Ctrl, Proportional Gain
14-31 Current Lim Ctrl, Integration Time
14-32 Current Lim Ctrl, Filter Time
14-35 Stall Protection
14-36 Field-weakening Function
14-37 Fieldweakening Speed
14-4* Energy Optimising
14-40 VT Level
14-41 AEO Minimum Magnetisation
14-42 Minimum AEO Frequency
14-43 Motor Cosphi
14-5* Environment
14-50 RFI Filter
14-51 DC-Link Compensation
14-52 Fan Control
14-53 Fan Monitor
MG33MO02
Programming Guide
ExpressionLimit
2 set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
Default value
4 set-up
[1] SFAVM
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] Off
All set-ups
[1] On
All set-ups
[0] No function
All set-ups
ExpressionLimit
All set-ups
[0] Trip
All set-ups
60 s
All set-ups
ExpressionLimit
All set-ups
100 %
All set-ups
[0] Manual reset
All set-ups
ExpressionLimit
All set-ups
[0] Normal operation
All set-ups
ExpressionLimit
2 set-ups
60 s
All set-ups
60 s
All set-ups
ExpressionLimit
All set-ups
[0] No action
All set-ups
0 N/A
All set-ups
100 %
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[1] Enabled
All set-ups
[0] Auto
All set-ups
ExpressionLimit
All set-ups
66 %
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[1] On
1 set-up
ExpressionLimit
All set-ups
[0] Auto
All set-ups
[1] Warning
All set-ups
Danfoss A/S © 01/2018 All rights reserved.
TRUE
0
FALSE
0
FALSE
0
FALSE
0
FC 302 only
Change
Conversio
during
n index
operation
TRUE
-
TRUE
-
FALSE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
0
TRUE
-
TRUE
0
TRUE
-3
x
TRUE
0
TRUE
-
TRUE
0
TRUE
-
FALSE
-
TRUE
0
TRUE
0
TRUE
0
TRUE
-
TRUE
0
FALSE
0
FALSE
-3
TRUE
-4
FALSE
-
x
TRUE
-
x
TRUE
67
FALSE
0
TRUE
0
TRUE
0
TRUE
-2
FALSE
-
TRUE
-
TRUE
-
TRUE
-
VisStr[
20]
Uint32
Uint32
Uint32
Type
5
5
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
Uint32
Uint32
Uint8
Uint16
Uint8
Uint16
Uint8
Uint8
Uint8
Uint8
Int32
Uint16
Uint16
Uint16
Uint8
Uint8
Uint16
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
Uint8
Uint8
243