Parameter Descriptions
0-20 Display Line 1.1 Small
Option:
[1664]
Analog Input 54
[1665]
Analog Output 42
3
3
[mA]
[1666]
Digital Output [bin] Binary value of all digital outputs.
[1667]
Freq. Input #29
[Hz]
[1668]
Freq. Input #33
[Hz]
[1669]
Pulse Output #27
[Hz]
[1670]
Pulse Output #29
[Hz]
[1671]
Relay Output [bin]
[1672]
Counter A
[1673]
Counter B
[1675]
Analog In X30/11
[1676]
Analog In X30/12
[1677]
Analog Out X30/8
[mA]
[1678]
Analog Out X45/1
[mA]
[1679]
Analog Out X45/3
[mA]
[1680]
Fieldbus CTW 1
[1682]
Fieldbus REF 1
[1684]
Comm. Option
STW
[1685]
FC Port CTW 1
[1686]
FC Port REF 1
[1687]
Bus Readout
Alarm/Warning
28
®
VLT
AutomationDrive FC 301/302
Function:
Actual value at input 54 either as
reference or protection value.
Actual value at output 42 in mA.
Use parameter 6-50 Terminal 42
Output to select the value to be
shown.
Actual value of the frequency
applied at terminal 29 as an
impulse input.
Actual value of the frequency
applied at terminal 33 as an
impulse input.
Actual value of impulses applied to
terminal 27 in digital output mode.
Actual value of impulses applied to
terminal 29 in digital output mode.
Application-dependent (for example
SLC control).
Application-dependent (for example
SLC control).
Actual value at input X30/11 either
as reference or protection value.
Actual value at input X30/12 either
as reference or protection value.
Actual value at output X30/8 in mA.
Use parameter 6-60 Terminal X30/8
Output to select the value to be
shown.
Control word (CTW) received from
the bus master.
Main reference value sent with
control word from the bus master.
Extended fieldbus communication
option status word.
Control word (CTW) received from
the bus master.
Status word (STW) sent to the bus
master.
Danfoss A/S © 01/2018 All rights reserved.
0-20 Display Line 1.1 Small
Option:
Function:
[1689]
Configurable
Alarm/Warning
Word
[1690]
Alarm Word
1 or more alarms in a hex code.
[1691]
Alarm Word 2
1 or more alarms in a hex code.
[1692]
Warning Word
1 or more warnings in a hex code.
[1693]
Warning Word 2
1 or more warnings in a hex code.
[1694]
Ext. Status Word
1 or more status conditions in a
hex code.
[1836]
Analog Input X48/2
[mA]
[1837]
Temp. Input X48/4
[1838]
Temp. Input X48/7
[1839]
Temp. Input
X48/10
[1860]
Digital Input 2
[3110]
Bypass Status Word
[3111]
Bypass Running
Hours
[4235]
S-CRC Value
[4282]
Safe Control Word
[4283]
Safe Status Word
[4285]
Active Safe Func.
[4286]
Safe Option Info
[9913]
Idle time
[9914]
Paramdb requests
in queue
[9917]
tCon1 time
[9918]
tCon2 time
[9919]
Time Optimize
Measure
[9920]
HS Temp. (PC1)
[9921]
HS Temp. (PC2)
[9922]
HS Temp. (PC3)
[9923]
HS Temp. (PC4)
[9924]
HS Temp. (PC5)
[9925]
HS Temp. (PC6)
[9926]
HS Temp. (PC7)
[9927]
HS Temp. (PC8)
[9951]
PC Debug 0
[9952]
PC Debug 1
[9953]
PC Debug 2
[9954]
PC Debug 3
[9955]
PC Debug 4
[9956]
Fan 1 Feedback
[9957]
Fan 2 Feedback
[9958]
PC Auxiliary Temp
[9959]