Danfoss VLT AutomationDrive FC 301 Programming Manual page 277

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Parameter Lists
16-90
Alarm Word
16-91
Alarm Word 2
16-92
Warning Word
16-93
Warning Word 2
16-94
Ext. Status Word
5.3.17 17-** Position Feedback
Par-
Parameter description
ameter #
17-1* Inc. Enc. Interface
17-10
Signal Type
17-11
Resolution (PPR)
17-2* Abs. Enc. Interface
17-20
Protocol Selection
17-21
Resolution (Positions/Rev)
17-22
Multiturn Revolutions
17-24
SSI Data Length
17-25
Clock Rate
17-26
SSI Data Format
17-34
HIPERFACE Baudrate
17-5* Resolver Interface
17-50
Poles
17-51
Input Voltage
17-52
Input Frequency
17-53
Transformation Ratio
17-56
Encoder Sim. Resolution
17-59
Resolver Interface
17-6* Monitoring and App.
17-60
Feedback Direction
17-61
Feedback Signal Monitoring
17-7* Position Scaling
17-70
Position Unit
17-71
Position Unit Scale
17-72
Position Unit Numerator
17-73
Position Unit Denominator
17-74
Position Offset
17-75
Position Recovery at Power-up
17-76
Position Axis Mode
17-77
Position Feedback Mode
17-8* Position Homing
17-80
Homing Function
17-81
Home Sync Function
17-82
Home Position
17-83
Homing Speed
17-84
Homing Torque Limit
17-85
Homing Timout
17-9* Position Config
17-90
Absolute Position Mode
17-91
Relative Position Mode
17-92
Position Control Selection
17-93
Master Offset Selection
17-94
Rotary Absolute Direction
MG33MO02
Programming Guide
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
Default value
[1] RS422 (5V TTL)
1024 N/A
[0] None
ExpressionLimit
1 N/A
13 N/A
260 kHz
[0] Gray code
[4] 9600
2 N/A
7 V
10 kHz
0.5 N/A
[0] Disabled
[0] Disabled
[0] Clockwise
[1] Warning
[0] pu
0 N/A
1024 N/A
1 N/A
0 CustomReadoutUnit2
[0] Off
[0] Linear Axis
[0] Relative
[0] No Homing
[0] 1st time after power
0 N/A
150 RPM
160 %
60 s
[0] Standard
[0] Target Position
[0] No operation
[0] Absolute Enabled
[0] Shortest
Danfoss A/S © 01/2018 All rights reserved.
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
4 set-up
FC 302
Change
only
during
operation
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
2 set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
0
Uint32
0
Uint32
0
Uint32
0
Uint32
0
Uint32
Conversi
Type
on index
5
5
-
Uint8
0
Uint16
-
Uint8
0
Uint32
0
Uint32
0
Uint8
3
Uint16
-
Uint8
-
Uint8
0
Uint8
-1
Uint8
2
Uint8
-1
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Int8
0
Int32
0
Int32
0
Int32
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Int32
67
Int16
0
Uint16
-1
Uint16
-
Uint8
-
Uint8
-
uint8
-
uint8
-
uint8
275